11.5.3 Main zone

EWSAH/X06UD
Daikin Altherma 3 WS
4P675765-1 – 2022.04
Setpoint screen
Control the leaving water temperature for the main zone via setpoint screen [2]

Main zone.

See
"11.3.5 Setpoint
screen" [
Schedule
Indicate if the temperature of the leaving water is defined according to a schedule
or not.
Influence of the LWT setpoint mode [2.4] is as follows:
In Fixed LWT setpoint mode, the scheduled actions consist of desired leaving
water temperatures, either preset or custom.
In Weather dependent LWT setpoint mode, the scheduled actions consist of
desired shift actions, either preset or custom.
#
Code
[2.1]
N/A
Heating schedule
Define a heating temperature schedule for the main zone via [2.2] Heating
schedule.
See
"11.3.7 Schedule screen:
Cooling schedule
Define a cooling temperature schedule for the main zone via [2.3] Cooling
schedule.
See
"11.3.7 Schedule screen:
Setpoint mode
Define the setpoint mode:
Fixed: the desired leaving water temperature does not depend on the outdoor
ambient temperature.
In WD
heating,
temperature:
-
depends on the outdoor ambient temperature for heating
-
does NOT depend on the outdoor ambient temperature for cooling
In Weather dependent mode, the desired leaving water temperature depends
on the outdoor ambient temperature.
#
Code
[2.4]
N/A
4
 147].
Schedule:
0: No
1: Yes
4
Example" [
 148].
4
Example" [
 148].
fixed
cooling mode, the desired leaving water
Setpoint mode:
Fixed
WD heating, fixed cooling
Weather dependent
11
Configuration
|
Description
Description
Installer reference guide
161