Please read all instructions before using. When using
an electrical appliance, basic precautions should
always be followed, including the following:
WARNING! To reduce the risk of fire, electric
shock or injury:
• Do not leave appliance when plugged in. Unplug
from outlet when not in use and before servicing.
• To reduce the risk of fire and electric shock due to
internal component damage, use only
Rug Doctor
cleaning products intended for use
®
with this appliance. See Cleaning Safety on page 3.
WARNING! To reduce the risk of electric shock,
use indoors only.
• Do not leave machine unattended when plugged
in or powered on. Unplug the machine when not in
use and before cleaning or servicing.
• Do not use if under the influence of alcohol or
drugs.
• Do not immerse. Use only on surfaces moistened
by cleaning process or small spills. Do not place
machine in standing water or try to clear flooded
areas.
• Do not use machine as a vacuum.
• This machine is designed to clean normally soiled
carpets in one cleaning pass, except berber
multi-level or looped carpets.
• Do not use more than two cleaning passes on any
area of carpet. Over-wetting and damage could
include permanent staining of carpet.
• Use caution when using hot tap water. Do not boil
or microwave water to be used in this machine.
PAGE 1 OF 9
1-800-295-5510
uline.com
®
SAFETY
• Do not allow the machine to run dry. When the
solution tank runs out, stop using and follow
directions to refill.
• Machine must not be used as a toy. Pay close
attention when used near children or animals. This
machine is not intended to be used by children
under the age of 18.
• Do not allow children or pets to place their body
parts in or near openings or moving parts.
• Do not use with damaged cord, plug or
attachment. If this machine is not working properly,
has been dropped, damaged, left outdoors,
rained on or immersed in water, do not use and
immediately contact Uline Customer Service at
1-800-295-5510.
• Do not pull by the cord. Do not carry machine by
the cord, use the cord as a handle, close a door
on the cord or pull the cord around sharp edges or
corners. Do not run machine over cord. Keep cord
away from heated surfaces.
• Do not unplug by pulling on the cord. Unplug by
pulling on the plug.
• Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the machine.
• Do not handle the plug or machine with wet or
sweaty hands.
• Do not put any objects into the opening. Do not
use the machine if any opening is blocked. Keep
openings free of dust, lint, hair and anything that
could reduce air flow.
• Keep hair, loose clothing, fingers and all parts of
the body away from openings and moving parts.
1123 IH-10972

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RUG DOCTOR H-10972 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for U-Line RUG DOCTOR H-10972

  • Page 1 π H-10972 1-800-295-5510 uline.com RUG DOCTOR ® CARPET CLEANER SAFETY Please read all instructions before using. When using • Do not allow the machine to run dry. When the an electrical appliance, basic precautions should solution tank runs out, stop using and follow always be followed, including the following: directions to refill.
  • Page 2 SAFETY CONTINUED • Turn off all controls before unplugging. WARNING! Machine may contain water. For best cleaning results, and to avoid the risk • Use extra care when cleaning on stairs. of permanent damage to property, carpets, floors and furniture, please follow the below •...
  • Page 3: Grounding Instructions

    SAFETY CONTINUED WARNING! Always exercise caution when • This appliance is rated for a nominal 120-volt emptying the dirty water tank. It is possible circuit and has a grounded plug. (See Figure 1) for the float and cage located within the dirty Ensure the machine is connected to an outlet with water tank to become dislodged during use the same configuration as the plug.
  • Page 4: Operation

    SAFETY CONTINUED • Do not put bleach, dye or products other than • Do not use the machine to vacuum large Rug Doctor cleaners in this machine. Use of quantities of liquid, such as a flooded basement or ® inappropriate products may cause this machine to large spills.
  • Page 5 OPERATION CONTINUED Spray Button Handle Release On/Off Switch Reset Button Dome Filter Recovery Latch and Dome Hood Lower Tank Upholstery Tool Recovery Tank Vacuum Slot SETUP 4. The lower tank capacity is Figure 5 three gallons. Fill the lower NOTE: Before cleaning, review machine safety tank with the Rug Doctor®...
  • Page 6: Upholstery Cleaning

    OPERATION CONTINUED IMPORTANT! When 2. Disconnect the large Figure 10 Figure 8 vacuum hose. Reconnect depressing the "press for spray" (red) button, keep the top portion to the large machine moving so the vacuum hose of hand tool. vibrating brush does not Slide up the brass agitate in one place.
  • Page 7: Care And Storage

    OPERATION CONTINUED 3. When cleaning is complete, switch the machine to 9. Clean the solution tank filter screen. After each use, "0" for the off position. inspect the rectangular filter screen located in the fill opening of the solution (lower) tank. If debris is 4.
  • Page 8: Troubleshooting

    TROUBLESHOOTING WARNING! Do not attempt repair on a machine NOTE: If you experience an operational under warranty. Servicing and warranty repairs problem, need replacement parts or repair is should be performed by an authorized service required, contact Uline Customer Service at representative only.
  • Page 9 TROUBLESHOOTING CONTINUED OPERATING ISSUE RECOMMENDATIONS Machine has lost Check the level of solution in the lower tank and refill if necessary. vacuum pressure. If the machine is on, and the spray button or hand tool lever is depressed but no spray is coming out: Ensure the ON switch is set to the appropriate setting –...

Table of Contents