Allen-Bradley A-B QUALITY DL20 Series User Manual page 86

Dataliner message display
Table of Contents

Advertisement

Chapter 7
The Parallel Port
Reducing Host
Output Requirements
11A
11B
D9
D8
11A
11B
D9
D8
7–14
If messages don't contain variable data, the number of outputs can be
reduced. Since no variable data is transferred, both strobe lines are always
zero, or always one. In addition, some data lines (D0 - D9) could be
eliminated depending on the highest message number used.
Figure 7.3 illustrates this method.
Figure 7.3
11 Ouput Configuration
12
13
14
15
D7
D6
D5
D4
PC Outputs (11)
You can further reduce the output requirements by tying the strobe lines high
as shown in Figure 7.4
Figure 7.4
10 Output Configuration
12
13
14
15
D7
D6
D5
D4
PC Outputs (10)
16
17
18
19
D3
D2
D1
D0
16
17
18
19
D3
D2
D1
D0
Terminal
21
20
23
Number
Terminal Block
MS0
MS1
GND
Designation
-
+
21
20
23
MS0
MS1
GND
-
+
Tie Together
For HIGH
TRUE Logic
Only
Power Supply
5-30 VDC
(Observe DC
Polarity)
Terminal
Number
Terminal Block
Designation
Power Supply
5-30 VDC
(Observe DC
Polarity)