  • Page 1 Industrial 17" CRT Monitor (Bulletin 6159 - Series B) Installation and User Manual...
  • Page 2: Table Of Contents

    Rockwell Automation cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation with respect to use of the information, circuits, equipment, or software described in this manual.
  • Page 3: Industrial 17" Crt Monitor

    ,QGXVWULDO ,QGXVWULDO    &57 0RQLW  &57 0RQLWR R U U The Bulletin 6159 17" Industrial CRT Monitor is a general purpose Description monitor suitable for a wide range of industrial computing applications. It offers the following features: •...
  • Page 4: Package Contents

    Industrial 17" CRT Monitor Available Options The following options are available to the 6159 Industrial Monitor: • Video interface options (HD-15) • Touchscreen options (resistive, capacitive) • Touchscreen cable options • Video cable options • Power cord options The monitor shipping carton contains the following items: Package Contents •...
  • Page 5: Installing The 6159 Industrial Monitor

    Industrial 17" CRT Monitor This section describes how to install the monitor. Installing the 6159 Industrial Monitor Tools Needed In addition to the tools required to make the cutout, you will need the following tools: • 3/8” Deep Well Socket •...
  • Page 6: Panel Mounting

    Industrial 17" CRT Monitor • Determine the minimum and maximum ambient humidity for the monitor by consulting the specification sheets at the back of this manual. Ensure that the humidity of the ambient air will not exceed these limits. In very dry environments, static charges build up very readily.
  • Page 7 Industrial 17" CRT Monitor Panel Mounting Guidelines Observe the following precautions before installing the unit in a panel: • Confirm that there is adequate space behind the panel. Remember to allow extra space (63.5 mm (2.5 in) behind and25.4 mm (1 in) below and on each side) for air circulation and cabling.
  • Page 8 Industrial 17" CRT Monitor Mounting the 6159 Industrial Monitor in a Rack Due to the front panel size and stud pattern, the 6159 Industrial Monitor can be installed in an EIA 19” 9U panel standard rack. Refer to the following figure: Figure 2 Generic Rack Mounting Diagram Important: If you install the 6159 Industrial Monitor in a rack, you...
  • Page 9 Industrial 17" CRT Monitor Dimensions This section provides diagrams you need to follow to install the unit. Figure 3 6159 Industrial Monitor Dimensions Publication 6159-5.1...
  • Page 10 Industrial 17" CRT Monitor Panel Mounting Procedure 1. Confirm that the shipping carton contains a package of 20 10-32 lock nuts and 20 flat washers. You will need 18 nuts and washers for installation. 2. Refer to the physical dimension drawing (Figure 3) and confirm that there is adequate space behind the panel.
  • Page 11 18 mounting studs. ATTENTION: Mounting nuts must be tightened to a torque of 24 inch-pounds to provide panel seal and avoid potential damage. Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure due to improper installation.
  • Page 12: Connecting The 6159 Industrial Monitor

    Industrial 17" CRT Monitor The rear panel of the 6159 Industrial Monitor has connectors for Connecting the 6159 attaching cables to accomplish the following: Industrial Monitor • Connecting to a host video source (HD-15 VGA) • Connecting to a host touchscreen control port (DE-9 connector) (optional) •...
  • Page 13 Industrial 17" CRT Monitor Connecting the Video Source The video connection to the host is made through a HD-15 (female) connector. To establish a signal using the HD-15 connector: Note: For more information on using an HD-15 video cable to connect to the host computer, refer to Appendix B (Page 33).
  • Page 14 Industrial 17" CRT Monitor Connecting the Touchscreen Interface The serial touchscreen interface connection to the host is made through an RS-232 DE-9 (female) connector located on the rear panel. The optional touchscreen provides a high-resolution touch input system. Driver software included with the package allows the touchscreen to function with many popular DOS and Windows -based industrial ®...
  • Page 15: Connecting Ac Power

    Industrial 17" CRT Monitor Connecting AC Power The 6159 Industrial Monitor requires a single phase power supply providing 100 to 240V AC at 50 or 60 Hz. Power must be available at a grounded three-pin outlet located nearby. Whenever possible, connect the monitor to the same AC source that supplies the computer.
  • Page 16: Operating The 6159 Industrial Monitor

    Industrial 17" CRT Monitor This section describes how to operate the 6159 Industrial Monitor. Operating the 6159 Industrial Monitor Operator Controls and Indicators The 6159 Industrial Monitor is furnished with operation keys on the front panel that allow digital on-screen adjustments. On-screen adjustments are performed from the main menu (see figure on following page).
  • Page 17: Status Leds

    Industrial 17" CRT Monitor Status LEDs The 6159 Industrial Monitor has two status LED indicators on the front panel. The following table lists the functions assigned to the LEDs: Table B 6159 Industrial Monitor Status LED Indicators Description • Power LED (Green) Indicates that power is applied to the monitor.
  • Page 18: Contrast Control

    Industrial 17" CRT Monitor Sample Procedure (Adjusting the Horizontal Position): 1. Press to display the main menu. 2. Use the arrow keys to maneuver to the icon. 3. Click on to display the adjustment box for horizontal position. 4. Use the arrow keys to reach the desired value. 5.
  • Page 19: Brightness Control

    Industrial 17" CRT Monitor Note: Pressing the arrow keys simultaneously sets the standard level. Using the Contrast adjustment box 1. Display the Contrast adjustment box. 2. Use the arrow keys to select a value. • < Press to decrease the contrast of the image. •...
  • Page 20: Memory Recall

    Industrial 17" CRT Monitor When the unit is left on for a long period, or is repositioned following power-up, the screen may pick up additional magnetic flux, causing colors to appear "blotchy" or otherwise distorted. For full effectiveness, allow at least fifteen minutes between manual degaussings. Shorter intervals may result in an incomplete removal of flux and residual color impurities.
  • Page 21: Horizontal Position

    Industrial 17" CRT Monitor Horizontal Position Centers the image horizontally on the screen. 1. Display the Horizontal Position adjustment box. 2. Use the arrow keys to select a value Note: Pressing toggles between the horizontal size and horizontal position control boxes. •...
  • Page 22: Vertical Position

    Industrial 17" CRT Monitor Vertical Position Centers the image vertically on the screen. Note: Pressing toggles between the vertical size and vertical position control boxes. 1. Display the Vertical Position adjustment box. 2. Use the arrow keys to select a value •...
  • Page 23 Industrial 17" CRT Monitor Vertical Pincushion Corrects the image for barrel distortion. 1. Display the Vertical Pincushion adjustment box. 2. Use the arrow keys to select a value • < Press to curve the screen image’s edges inwards. • > Press to curve the screen image’s edges outwards.
  • Page 24: Color Temperature

    Industrial 17" CRT Monitor Rotation Adjusts for tilt of the image on the screen. 1. Display the Rotation adjustment box. 2. Use the arrow keys to select a value • < Press to tilt the image to the left. • >...
  • Page 25: Video Input Level

    Industrial 17" CRT Monitor 5. To adjust the value, press to advance to the appropriate color. < > Press the arrow keys to adjust the value of the selected color (0-255). 6. Press the key to memorize the settings and complete the adjustments.
  • Page 26 Industrial 17" CRT Monitor Self-Test Menu (NO SIGNAL screen) Figure 8 Self-Test Menu This screen indicates that the monitor is working properly. Press one of the 4 front panel operation keys to call the appropriate adjustment box if one of the following conditions occur: •...
  • Page 27: Routine Maintenance

    Industrial 17" CRT Monitor Routine Maintenance Cleaning Occasionally clean the display panel and cabinet with a soft cloth dampened (not soaked) with a mild (non-abrasive) glass cleaner. Keep turning a fresh side of the cloth toward the screen surface to avoid scratching it with accumulated grit.
  • Page 28: Troubleshooting

    Industrial 17" CRT Monitor You can refer to this table to help identify the cause and offer a solution Troubleshooting to a problem. This table lists typical problems you may encounter. Table D Troubleshooting Table Symptom Possible Problem Action No screen image and the green power Open power switch.
  • Page 29 NOTE: Do not confuse the flicker associated with an interlaced video mode Ask Rockwell Automation about various shielding with jitter. options available to protect the monitor. Display is present, but “bars” appear “Noise”...
  • Page 30: Appendix A: Touchscreen Serial Interface

    For Allen-Bradley monitors equipped with touchscreens, a serial communications cable is required. A suitable cable can be obtained from Rockwell Automation or you can create one. The cable provides a communications channel between the touchscreen controller, which is mounted inside the monitor, and an RS-232-C serial port on the host computer.
  • Page 31 Industrial 17" CRT Monitor Interconnecting wiring to the host serial port connection is shown in the following table. Table E Touchscreen Interface Monitor (DCE Device) Host (DTE Device) DE-9 (Female) Signal Description DE-9 (Male) DB-25 (Male) Not Connected (DCD) Transmit Data (TXD) Receive Data (RXD) Data Terminal Ready (DTR) Common Signal Return (SG)
  • Page 32: Performing A Calibration

    Industrial 17" CRT Monitor Once you have obtained this information, install the software using the installation disks found in the touchscreen accessory package. Note: Before installation, you may want to check the touchscreen manufacturer’s site on the World Wide Web for the latest software drivers.
  • Page 33: Appendix B: Video Cables

    Industrial 17" CRT Monitor $ SSHQGL[ % SSHQGL[ % 9 9 LGHR & LGHR &D D EOHV EOHV You use an HD-15 video cable equipped with a conventional HD-15 connector at each end to connect the 6159 Industrial Monitor to the host computer.
  • Page 34: Specifications

    Industrial 17" CRT Monitor Specifications Display CRT Type 17” diagonal flat square, 0.27mm dot pitch RGB short persistence (Hi-EU Red)/Dark TINT, Tension-band implosion protected Degaussing Manual and automatic Nominal Display Area (4:3 aspect) Horizontal 11.8in. (300mm +/- 3mm) (4:3 aspect) Vertical 8.9in.
  • Page 35 Industrial 17" CRT Monitor Environmental Panel Rating NEMA 4/12, designed to IP65 standards Operating Temperature 0C to 40C Storage Temperature -20C to 60C Relative Humidity 5% to 90% non-condensing Operating Altitude Sea level to 10,000 ft (3048m) Non-Operating Altitude Sea level to 40,000 ft (12000m) Operating Electrostatic 8.0K VDC (IEC 801-2, level 3) Discharge...
  • Page 36 Rockwell Automation Headquarters, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414 382-2000, Fax: (1) 414 382-4444 Rockwell Automation European Headquarters, Avenue Hermann Debroux, 46 1160 Brussels, Belgium, Tel: (32) 2 663 06 00, Fax: (32) 2 663 06 40 Rockwell Automation Asia Pacific Headquarters, 27/F Citicorp Centre, 18 Whitfield Road, Causeway Bay, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 World Wide Web: http://www.ab.com...