Allen-Bradley A-B QUALITY DL20 Series User Manual page 171

Dataliner message display
Table of Contents

Advertisement

D9 D8 D7 D6 D5 D4
DL20 Terminals
Figure G.6
DL20 to DC Output Module (Catalog No. 1771-OB, -OG)
+5
VDC
OUT
D3 D2
D1
DO
MS1 MS0
1771-OB DC Output Modules (12-24 VDC)
1771-OG DC Output Modules (5VDC)
Set both internal switches in the OG module ON for
high true logic.
Important Note: The 1771-OG TTL output modules 5VDC signals are
more noise susceptible than 12-24 DC signals. In applications where noise
may be a problem, it is strongly recommended that a 1771-OB DC output
module be used.
ATTENTION: Do not connect to terminal 22 (+5 VDC OUT).
Applying any voltage to this terminal will damage the DL20.
!
Appendix G
Application Notes
GND
+ 12-24 VDC (OB) -
or
+
5 VDC (OG)
00-07
10-17
A
A
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
or
-