Parallel Port Connectors - Allen-Bradley A-B QUALITY DL20 Series User Manual

Dataliner message display
Table of Contents

Advertisement

Chapter Objectives
Parallel Port Description
The Parallel Port
This chapter describes the parallel port:
Data formats
Electrical requirements
Timing requirements
AC input converters
Sampling modes
The DL20 can connect to a programmable controller with parallel outputs.
These outputs can trigger messages and transfer variable data.
Figure 7.1 shows the parallel port terminals.
Figure 7.1

Parallel Port Connectors

ETS
ETS
D9
D8
-
+
10
11
11A 11B 12
Refer to Chapter 9 for wiring connections.
The parallel input accepts either binary or BCD data formats to transfer data.
The parallel input consists of 12 terminals, divided into two groups.
Terminals in the first group, numbering 10, are known as data lines.
The remaining two are known as strobe lines. The data terminals are
designated D0 through D9. Where data line D0 is known as the least
significant line. The strobe lines are designated MS0 and MS1.
7
Chapter
A–B
PARALLEL INPUT PORT
D7
D6
D5
D4
D3
D2
D1 D0
13
14
15
16
17
18
+5
VDC
MS1 MS0
OUT GND
19
20
21
22
23
7–1