GAS BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
4.
Pull temperature dial from potentiometer shaft
and remove mounting nut.
5.
To install:
A.
Align tab on potentiometer with positioning
bracket on panel.
B.
Install mounting nut and tighten.
C.
Adjust stop nut on potentiometer body (as
necessary) to ensure a water tight seal on
mounting nut.
D.
Attach temperature dial.
6.
Reverse procedure from step 3 to complete the
installation.
F25121 (February 2003)
7.
Check calibration as outlined under
TEMPERATURE CONTROLLER
CALIBRATION.
PAN POSITION/DOWN LIMIT
1.
Remove front and left side panels as outlined
under COVERS AND PANELS.
2.
Disconnect conduit and remove pan
position/down limit switch from switch mounting
bracket.
LEFT SIDE VIEW SHOWN
3.
Remove cover from switch.
4.
Disconnect lead wires and pull wires thru
conduit elbow assembly.
5.
Remove conduit elbow assembly from switch.
Page 6 of 32
SWITCH
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.