GAS BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
6.
Reverse procedure to install and check for
proper operation.
NOTE: When installing: Route thermocouple wire in
the same manner thru the metal clamps on the hinge
& frame. Tighten thermocouple just until it touches
the pan; do not over tighten or damage to the
thermocouple may occur.

DC LIFT MOTOR

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove front, rear and right side panels as
outlined under COVERS AND PANELS.
2.
Remove power supply box cover.
3.
Disconnect DC lift motor lead wires labeled
MTR+ (positive) & MTR - (negative).
NOTE: Lead wires can be identified by label or
marking on the wire.
4.
Loosen the strain relief nut and the hold down
clamps for the motors' power cable. Pull the
cable thru the strain relief opening and remove
the cable form underneath the clamps.
VG30 REAR VIEW SHOWN
5.
Remove motor mounting bolts from gear
reducer flange.
6.
Remove motor from gear reducer.