Switch Hysteresis Mode
The switching behavior is determined by entering a switching point and an associated hysteresis value.
RH [%]
Switching point
Hysteresis
open
Terminal 1-2 / 4-5
closed
open
Terminal 2-3 / 5-6
closed
Fig. 17
Example hysteresis mode on both alarm outputs using normal state standard
Additionally, detected errors are signaled at the alarm output.
Error occurs
No error
RH [%]
Switching point
Hysteresis
open
Terminal 2-3
closed
open
Terminal 5-6
closed
Fig. 18
Example of hysteresis mode with error occurring.
Switch Window Mode
The switching behavior is determined by entering two switching points and two associated hysteresis values.
RH [%]
Switching point 2
Hysteresis 2
Switching point 1
Hysteresis 1
open
Terminal 1-2 / 4-5
closed
open
Terminal 2-3 / 5-6
closed
Fig. 19
Example window mode on both alarm outputs using normal state standard
Additionally, detected errors are signaled at the alarm output.
t
Normal state: Standard
Normal state: Standard
t
Normal state: Standard
Normal state: Inverted
t
Normal state: Standard
Normal state: Standard
User Manual EE310