Download Print this page

Tektronix DC 501 Instruction Manual page 7

100 mhz counter
Hide thumbs Also See for DC 501:

Advertisement

Operating Instructions—
DC
501
Fig
1-2.
Two
examples
of
triggering circuit
output showing
how
proper adjustment
of
TRIGGERING LEVEL
control
can
avoid an
erroneous count.
The
DISPLAY TIME
control
sets
the
length
of
time
a
measurement
can be
held
in
the
counter and
displayed.
The
HOLD
detent
position allows
a
measurement
to
be
held
indefinitely,
or
until
the
counter
is
reset
to zero
by
the
front-panel
RESET
button.
Count;
Register capacity,
10';
totalizes
events
accumu-
lated
between
start/stop
commands
from
front-panel
button.
INPUT
Frequency,
10
Hz
to
100
MHz;
sensitivity,
300
mV
peak
to peak;
triggering
level,
adjustable
+2V;
attenuator,
XI,
X5, XIO,
or
X50;
maximum
input
voltage,
500
V
(DC
-i-
peak
AC,
or
peak
to
peak
AC)
at
1
kHz
or
less;
impedance,
(EXT
input),
approx
1
MO
paralleled
by about
20 pF
(INT
input)
approx
5012
paralleled
by about 20
pF;
coupling,
AC.
INTERNAL
TIME BASE
Standard
Option
1
Crystal
Frequency
1
MHz
5
MHz
Stability
(0°C
to
-i-50°C),
after
1/2
hour
warm-up
Within
1
part
in
10®
Within
5
parts
in
10'.
Long-term
Drift
1
part or
less in
10^
per
month
1
part or
less in
10'
per
month
Accuracy
Adjustable
to
within
1
part
in
10'
Adjustable
to
within
5
parts
in
109.
INTERNAL
MEASUREMENT
INTERVAL.
Selectable
in
decade
steps.
Optional Features
Option
1-0.5
P/M
5
MHz
Crystal Oscillator.
The
DC
501
can
be
ordered
with
a
temperature-compensated
crystal
oscillator
to
provide
a
highly
stable
and
precise
internal
time
base
TMHz
clock.
This option
includes
a
divide-by-five
1C counter
to provide the
proper output.
Option
2-Automatic
Gate Control and
Readout
Scaling
Circuit.
This
circuit
automatically
selects
the
0.1
-,
1-,
or
10-second
measurement
interval
to
display
the
largest
number
of
digits
without
overflow,
and
provides the
appropriate
scaling
of
decimal-point
and
units
lights
to
produce
the correct
display.
If
overflow
indication occurs,
the input
signal
is
>
100
MHz
and
the
overflow
digit
is
a
"
1
".
Measurement
Interval
Display
Units
Resolution
10
ms
000.0000
MHz
100
Hz
100
ms
00.00000
MHz
10
Hz
1
s
0000.000
kHz
1
Hz
10s
000.0000
kHz
0.1
Hz
Manual
0000000
(adds to displayed
number)
Accuracy, within ±
;
± time-base
accuracy.
total
count
DATA
PRESENTATION
Visual
numerical readout, seven 7-segment
LED
with
automatically positioned decimal
point;
units,
LED
indi-
cates
kHz
or
MHz;
overflow,
LED
indicates that
readout
is
exceeded;
gate,
LED
indicates
open
gate.
Electrical
Characteristics
MEASUREMENT
RANGES
AND ACCURACY
Frequency:
10
Hz
to
100
MHz;
0.1-s
to 10-s
counting
gate time; displays
kHz
or
MHz
units
with
positioned
decimal
point.
Accuracy, ±1 count
±
time-base accuracy.
DATA
INPUTS
and
OUTPUTS
Available
via
plug-in
connector
to
50-pin
connector
at
rear
of
Power
Module.
Input
lines
are available for signal
input,
and
internal
and
external scan
clock
control.
Output
lines
are available for
BCD
output
(serial-by-digit),
and
to
indicate status of timing,
data
good,
reset, scale,
decimal
point
and
overflow.
1-3