What to do "When..."

6. WHAT TO DO "WHEN..."
When...
The pump does not start
No flow
The pump does not turn off
Insufficient flow
The pump turns off after a short
time
NOTE:
Not covered by the warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects in the
water
Blocking the running of the wheel with foreign objects
Damage during transport
Damage caused by unprofessional alterations
Causes
No power supply.
The float won't switch.
The check valve is choked.
The pressure hose is bent.
The float cannot drop.
The check valve is choked.
Reduced pump capacity due to dirty and
contaminated water.
The temperature fuse stops the pump due
to dirty water.
The water is too hot. The temperature fuse
stops the pump.
Repairs
Check the power supply.
Check if the float got stuck.
Clean the check valve.
Straighten the hose.
Check if the float got stuck.
Clean the check valve.
Clean the pump and flush the hose with
clean water.
Disconnect the power plug. Clean the
pump and the pumping pit.
Check that the maximum water
temperature of 35°C is not exceeded.