2. Pump installation
always hang the pump on the eye on the top of the pump (Fig. 5, point 1). Always use a silk rope with the
appropriate load capacity for hanging (Fig. 5, point 2)
When installing at a depth greater than 5 m, secure the supply cable (Fig. 5, point 3) to the suspension rope
with plastic tie straps.
ATTENTION! Never install the pump by hanging it on the outlet hose or power cord without additional
support. For proper pump operation, the fluid must not contain any solid impurities
The pump must be submerged at least 150 mm below the surface and at the same time 30 cm above the
bottom (Fig. 6)
The level at which the pump switches on and off can be set by fixing the float in the pump clip. (Fig. 7)
The pump can operate in manual mode, i.e. it does not switch off automatically. To do this, fix the float to the
pump (Fig. 8)
ATTENTION! The pump must not be dry operated.
ATTENTION! Risk of dry running – The pump is cooled using the pumped liquid.
In the event of dry running, the pump motor may burn up.

5. MAINTENANCE AND STORAGE

This submersible pump is approved as a maintenance-free product undergoing several final inspections. We
recommend you perform regular inspections and maintenance, which will ensure a long lifetime and continuous
performance.
ATTENTION! Disconnect the power source before performing any maintenance.

Maintenance

If the pump is regularly moved during operation, it should be rinsed out after each use with clean water.
If the pump is permanently installed, the working order of the float switch should be checked every 3 months.
Any fibrous deposits that could deposit themselves inside the pump, should be removed using a water
current.
If an excessive amount of debris accumulates in the body of the pump, flush the pump out with clean water.
The protective cover serving as a filter should be cleaned regularly (Fig. 9.)

Storage

Store the thoroughly cleaned out pump in a dry place out of children's reach.