6. TECHNICAL SPECIFICATIONS

Voltage/Frequency
Power input
Maximum transferred amount
Maximum delivery
Maximum submersible depth
Maximum temperature of the media
Maximum value of solid particles in the media
Height of the switching point: On
Height of the switching point: Turned off

7. WHAT TO DO "WHEN..."

When...
The pump does not start
Not fl owing
The pump does not
turn off
Insuffi cient fl ow
The pump turns off
after a short time
Note: Not covered by warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects
in the water
Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons
Causes
– No power supply
– The fl oat does not switch
– The suction sieve is clogged
– The pressure hose is bent
– The fl oat cannot fall lower
– The suction sieve is clogged
– Lowered pump capacity due to dirty
and silted water
– The temperature fuse stops the
pump due to dirty water
– The water is too hot. The temperature
fuse stops the pump
FVC 2001-EK
230 V ~ 50 HZ
250 W
5000 l/h
6 m
5 m
35 °C
Dia. 5 mm
Approx. 50 cm
Approx. 5 cm
– Check the power supply
– Move the fl oat to a higher position
– Flush out the suction sieve with
a current of water
– Straighten the hose
– Place the pump correctly
on the fl oor of the tank
– Clean the suction sieve
– Clean the pump and fl ush the hose
with clean water
– Disconnect the power plug.
Clean the pump and the pumping pit
– Check that the maximum water
temperature of 35 °C is not exceeded
FVC 2003-EK
230 V ~ 50 HZ
400 W
7500 l/h
5 m
5 m
35 °C
Dia. 35 mm
Approx. 50 cm
Approx. 5 cm