(5) Motor temperature detection signal (when using a dedicated vector motor with thermistor
and FR-A7AZ)
The change applies to the December 2010 production or later.
When using a dedicated vector motor with thermistor (SF-V5RUT/A) and FR-A7AZ, motor temperature detection is
available. When motor temperature exceeds the detection level, motor temperature detection signal (Y55) is output. (Set Pr.
407 Motor temperature detection filter  "9999")
Set "55 (positive logic)" or "155 (negative logic)" in the following parameters to output the motor temperature detection signal
(Y55) when motor temperature exceeds the detection level.
Parameter
Number
190
RUN terminal function selection
191
SU terminal function selection
192
IPF terminal function selection
193
OL terminal function selection
194
FU terminal function selection
195
ABC1 terminal function selection
196
ABC2 terminal function selection
313 to 319
DO0 to DO6 output selection
*1
320
RA1 output selection
*2
321
RA2 output selection
*2
322
RA3 output selection
*2
*1
Read/write is enabled when using FR-A7AY.
*2
Read/write is enabled when using FR-A7AR.
Use the following parameter to adjust the temperature to output the motor temperature detection signal (Y55).
Parameter
Number
750 *
Motor temperature detection level
*
Read/write is enabled when using FR-A7AZ.
492
Initial
Name
Value
0
1
2
3
4
99
9999
9999
0
1
2
Initial
Name
Value
75°C
Pr. 750
OFF
Y55
Y55 signal turns OFF when motor temperature
become Pr. 750 or less (with hysteresis).
Initial signal
0 to 8, 10 to 20, 25 to 28, 30 to 36,
39, 41 to 47, 55, 64, 70, 84, 85,
90 to 99, 100 to 108, 110 to 116, 120,
125 to 128, 130 to 136, 139,
141 to 147, 155, 164, 170, 184, 185,
190 to 199, 9999
0 to 8, 10 to 20, 25 to 28, 30 to 36,
39, 41 to 47, 55, 64, 70, 84, 85, 90,
91, 94 to 99, 100 to 108, 110 to 116,
120, 125 to 128, 130 to 136, 139,
141 to 147, 155, 164, 170, 184, 185,
190, 191, 194 to 199, 9999
0 to 8, 10 to 20, 25 to 28, 30 to 36,
39, 41 to 47, 55, 64, 70, 84 to 99,
100 to 108, 110 to 116, 120,
125 to 128, 130 to 136, 139,
141 to 147, 155, 164, 170,
184 to 199, 9999
0 to 8, 10 to 20, 25 to 28, 30 to 36,
39, 41 to 47, 55, 64, 70, 84 to 91,
94 to 99, 9999
Setting
Range
Set temperature when the motor temperature
0 to 200°C
detection signal (Y55) is output.
Hysteresis range (5 C)
Motor temperature
Time
ON
OFF
Setting Range
55: Motor temperature
detection signal
(positive logic)
155:Motor temperature
detection signal
(negative logic)
55: Motor temperature
detection signal
(positive logic)
Description