Mitsubishi Electric FR-A720-00030-NA Instruction Manual page 270

Table of Contents

Advertisement

Types of Monitor
Increments
0.01kW/
Motor output
0.1kW
Feedback pulse
*3, *8
SSCNET III
communication
1
status
*10
Motor temperature
1ºC
*11
Power saving effect
Variable
according to
Cumulative saving
parameters
power
*8
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
PLC function output
0.1%
*1
Frequency setting to output terminal status on the PU main monitor are selected by "other monitor selection" of the parameter unit (FR-PU04 , FR-PU07 ).
*2
Position pulse and orientation status function when used with the FR-A7AP/FR-A7AL (option). When orientation control is invalid, "0" remains
displayed and these functions are invalid.
*3
Feedback pulse functions when the FR-A7AP/FR-A7AL (option) is used and vector control is performed.
*4
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
When the operation panel (FR-DU07) is used, the time is displayed up to 65.53 (65530h) in the indication of 1h = 0.001, and thereafter, it is added
up from 0.
*5
The actual operation time is not added up if the cumulative operation time before power supply-off is less than 1h.
*6
When using the parameter unit (FR-PU04/FR-PU07), "kW" is displayed.
*7
The setting depends on the inverter capacity. (FR-A720-02150(FR-A740-01100) or less / FR-A720-02880(FR-A740-01440) or more)
*8
Since the panel display of the operation panel (FR-DU07) is 4 digits in length, the monitor value of more than "9999" is displayed as "----".
*9
When the output current is less than the specified current level (5% of the rated inverter current), the output current is monitored as 0A. Therefore,
the monitored value of an output current and output power may be displayed as "0" when using a much smaller-capacity motor compared to the
inverter or in other instances that cause the output current to fall below the specified value.
*10 This function is valid when the FR-A7NS (option) is mounted.
*11 This function is valid when the FR-A7AZ (option) is mounted.
Pr. 52 Setting
Pr. 54 (FM)
Pr. 158 (AM)
PU main
DU LED
Setting
monitor
34
*7
35
39
46
50
51
52
53
54
*1
55
*1
56
57
Monitor display and monitor output signal
Full-scale
Value of the
Terminal FM
and AM
Multiply the motor speed by the then output
Rated motor
34
torque and display the machine output of the
capacity
motor shaft end
Display the number of pulses fed back from
the encoder during one sampling (display
during a stop).
The sampling time varies with the Pr.369
Number of encoder pulses setting.
1050 or less: 1s
1051 to 2100: 0.5s
2101 to 4096: 0.25s
Display the SSCNET III communication
status.
Display the temperature of the vector control
46
Pr. 751
dedicated motor with thermistor (SF-
V5RUT/A)
Inverter
Display energy saving effect monitor
50
capacity
You can change the monitor to power saving,
power saving average value, charge display
and % display using parameters.
(For details, refer to page 284)
52
100%
Display the set point, measured value and
53
100%
deviation during PID control (For details, refer
to page 374)
Display the input terminal ON/OFF status on
the PU (refer to page 261 for DU display)
Display the output terminal ON/OFF status
on the PU (refer to page 261 for DU display)
Display the input terminal ON/OFF status of
the digital input option (FR-A7AX) on the DU
(refer to page 261 for details)
Display the output terminal ON/OFF states of
the digital output option (FR-A7AY) or relay
output option (FR-A7AR) on the DU (refer to
page 261 for details)
Desired values can be output from terminal
FM and AM using the PLC function.
70
100%
Refer to the FR-A700 PLC function
programming manual for details of the PLC
function.
Description
259
4