Dalsa Piranha4 User Manual page 91

Hide thumbs Also See for Piranha4:
Table of Contents

Advertisement

Full Name
Calibrate Flatfield
Mnemonic
CPA
Argument(s)
Algorithm
# of lines to average
Target
Description
Calibrate user PRNU flat field coefficients
Notes
Disable Esc Key
Full Name
DEK
Mnemonic
Mode
Argument(s)
Allow the use of the Esc key to be disabled so that upon boot-up the camera will directly enter
Description
the ASCII command mode. With the Esc key disabled the GENCP cannot be accessed.
Notes
To access the GenCP, you have to first issue the DEK 0 command in order to enable the
ESC key. Then reboot the camera.
Full Name
Device Scan Type
Mnemonic
DST
Argument(s)
Mode
Description
Use this command to switch between Area and Single Line modes.
Notes
Perform flat field calibration using the average of <# lines>.
With filter algorithm this average line is then smoothed and outlier pixels are
interpolated. Use this feature if your white reference is not featureless.
Adjust pixel gain such that output will be <target>.
The target is first divided by horizontal binning factor and gain and then the
offset is subtracted. Therefore the output will go to the target.
Because the PRNU can be less than 1, the target may be below the current
maximum value.
Coefficients are saved and loaded with user set (e.g. USS / USL)
STG must equal 1 to enter the area mode DST = 1
0. Basic
1. Low-pass Filter
2048
4096
0 to 4095 DN in 12 bit mode
0 to 1023 DN in 10 bit mode
0 to 255 DN in 8 bit mode
0. Esc key is enabled
1. Esc key is disabled
0. Line Scan
1. Area Scan

Advertisement

Table of Contents
loading

This manual is also suitable for:

P4-cm-8k070-00-r

Table of Contents