SECTION 6:
MAINTENANCE
DAILY PROCEDURE
The burner should
cease
firing
at
the low
bo
iler
water
cutoff
level.
Investigate and correct
a failure of
the
burner
to cease
firing
at that
water
level.
The steam injection system includes
a steam
trap
which purges
condensate
from the steam
piping.
Verify that
this trap
is
operating. Correct
any failure
immediately.
Check
fuel supply system.
Check
oil supply system.
Check compressor lubncat1on.
Check lmkage
for
tightness
and
ease
ot
travel.
Observe flame and check stack
temperature.
If flame apbears abnormal or
stack temperature is above
500°F,
have
a
qualified Tur
aFire®
II service
technician inspect the burner.
WEEKLY PROCEDURE
Check program controller for proper sequencing.
Check llm1t
controls
to determme
proper
operation.
Check oil
nozzle.
Check all alarms associated
w1th
the control system.
Tighten burner mounting flange.
Check flue gas
compos1t1on.