SECTION 6:
MAINTENANCE
DAILY PROCEDURE
•
The burner should
cease
firing
at
the low
bo
iler
water
cutoff
level.
Investigate and correct
a failure of
the
burner
to cease
firing
at that
water
level.
•
The steam injection system includes
a steam
trap
which purges
condensate
from the steam
piping.
Verify that
this trap
is
operating. Correct
any failure
immediately.
•
Check
fuel supply system.
•
Check
oil supply system.
•
Check compressor lubncat1on.
•
Check lmkage
for
tightness
and
ease
ot
travel.
•
Observe flame and check stack
temperature.
If flame apbears abnormal or
stack temperature is above
500°F,
have
a
qualified Tur
aFire®
II service
technician inspect the burner.
WEEKLY PROCEDURE
•
Check program controller for proper sequencing.
•
Check llm1t
controls
to determme
proper
operation.
•
Check oil
nozzle.
•
Check all alarms associated
w1th
the control system.
•
Tighten burner mounting flange.
•
Check flue gas
compos1t1on.
24
TurboFire® U
Bumer