MULTICAL® 403
11.2 Modules
11.2.1 HC-003-10: Data Pulse, inputs (In-A, In-B)
Data Pulse module enables direct communication to the meter using the KMP protocol.
The module requires a special Kamstrup adapter cable for either RS-232 or USB in order to exchange data.
For information about the KMP protocol, see chapter 12.3
11.2.2 HC-003-11: Data Pulse, outputs (Out-C, Out-D)
Data Pulse module enables direct communication to the meter using the KMP protocol.
The module requires a special Kamstrup adapter cable for either RS-232 or USB in order to exchange data.
For information about the KMP protocol, see chapter 12.3
11.2.3 HC-003-20: Wired M-Bus, inputs (In-A, In-B)
Wired M-Bus enables communication to battery supplied meters, without affecting the battery lifetime.
The Wired M-Bus module supports primary, secondary and enhanced secondary M-Bus addressing. The module
supports automatic baud rate selection among 300,2400,9600 and 19200 baud.
A large selection of datagrams for various applications can be configured into the M-Bus module.