  • Page 1 INSTRUCTION MANUAL Emergency Stop Box 13-00005A MODEL NOISE LABORATORY CO., LTD. Edition 1.02 AEY00043-00E-0C...
  • Page 2 NOTICE • The contents of this instruction manual (the “Manual”) are subject to change without prior notice. • No part of the Manual may be reproduced or distributed, in any form or by any means, without the authorization of Noise Laboratory Co., Ltd. (the “Company”).
  • Page 3: Important Safety Precautions

    The following instructions are very important for safe handling of the emergency stop box 13-00005A (hereinafter “the Unit”). They must be kept strictly to prevent users of the Unit from receiving harm or damage through using the Unit. Read them carefully before use.
  • Page 4 Memorandum...
  • Page 5: Application Form For Instruction Manual

    2. APPLICATION FORM FOR INSTRUCTION MANUAL We place an order for an instruction manual. Model:13-00005A Serial No.: Applicant: Company name: Address: Department: Person in charge: Tel No.: Fax No. Cut off this page “APPLICATION FORM FOR INSTRUCTION MANUAL” from this volume and keep it for future use with care.
  • Page 6 Memorandum...
  • Page 7: Preface

    3. PREFACE We thank you very much for your purchase of our Emergency Stop Box 13-00005A (hereinafter “the Unit”). This instruction manual (“the Manual”) contains how to use the Unit and other important information. In order to obtain the highest performance from the Unit, thoroughly understand the contents of the Manual and use as ready reference for operation.
  • Page 8: Table Of Contents

    4. CONTENTS IMPORTANT SAFETY PRECAUTIONS ................1 APPLICATION FORM FOR INSTRUCTION MANUAL ............3 PREFACE ..........................5 3-1..........................5 EATURE CONTENTS ..........................6 BASIC SAFETY PRECAUTIONS ................... 7 5- - - - 1......................7 YMBOLS OF AZARD 5- - - - 2.............
  • Page 9: Basic Safety Precautions

    5. BASIC SAFETY PRECAUTIONS The following items are very important instructions which users must follow to take precautions against possible injury and harm. The indications are provided as an explanation of potential danger involved if the safety precautions are not observed correctly. 5-...
  • Page 10 BASIC SAFETY PRECAUTIONS DANGER Do not take the Unit apart or do not remodel. Do not open the cover. Imminent danger might occur resulting in death or serious injury. Repair, internal adjustment, and inspection of the Unit should be performed by a qualified service Do not engineer.
  • Page 11 BASIC SAFETY PRECAUTIONS Use the Unit after understanding instructions in the Manual fully. There may be danger causing a fatal or serious wound or emitting over-ristricted-value electromagnetic noise in using the Unit. NOISE LABORATORY and its sales agents shall have no liability against any accident resulting in injury or death, any damage to equipment or any resultant damage thereof, which is caused by abuse or careless handling of this unit.
  • Page 12 BASIC SAFETY PRECAUTIONS Do not put any substance into the Unit or its connectors. If some metal or flammable things are put into the Unit through a connector or a vent, it may result in a fire or an electric shock. Do not install the Unit on the spot where quick operation of power key or STOP key is difficult.
  • Page 13 BASIC SAFETY PRECAUTIONS CAUTION If dewing occurs, fully dry up the Unit before using it. Dews may cause an electric shock, a trouble, or a fire. Use the Unit in proper environment. Operating temperature range is 15~35ºC. Operating humidity range is 25~75%. If these precautions are not followed, the unit may be broken or the prescribed performance may not be warranted.
  • Page 14 BASIC SAFETY PRECAUTIONS Do not install the Unit on following places. Setting up the Unit on wrong places as follows may result in a fire, an electric shock, or an injury. A very humid or dusty place A hot place, e.g. a place exposed to direct rays of the sun, a place close to a heater.
  • Page 15: Included Accessories

    6. INCLUDED ACCESSORIES The following accessories are included in the purchase package A:AC cord ······················································· 1 B:Short-bar (OSP-10 by Osada) ·························· 2 C:N-connector 50-ohm terminated ······················· 1 D:BNC connector with a short-connection cap ········ 1 E:D-Sub 9-pin connector cable (5m) ····················· 1...
  • Page 16: Controls And Indicators

    7. CONTROLS AND INDICATORS ②INTERLOCK ④RESET button setting button ① POWER key ⑤ EMERGENCY STOP button ③DOOR status indicator ①:POWER key The main POWER key for this device ②:INTERLOCK setting button Provides a selection between SYNC (operational) and ASYNC (non-operational) for ⑧DOOR terminals on the rear panel.
  • Page 17 ⑪EXT CNT ⑥SG connection relay ⑫PC connector ⑬AC inlet ⑦AMP 1 to 4 ⑧DOOR terminals INTERLOCK ⑩RESET terminals ⑨EXT EMERGENCY connector ⑥:SG connection relay The SG (signal generator) output is connected to SG IN, and SG OUT is connected to the amplifier input and attach the supplied 50-ohm terminated N connector to 50Ω...
  • Page 18 ⑫:PC connector The PC where NETS software has been installed is informed that the system is in Emergency Stop status. ⑬:AC input The AC power input for this device. Connect the supplied AC cord.
  • Page 19: Operation

    8. OPERATION 1.Make the required connections. 2.Turn on this device by pressing the POWER key to [I] side. 3.Select the desired mode for interlock setting of SYNC or ASYINC by using ② INTERLOCK setting button. 4.Select SG IN to SG OUT path by pressing ④RESET button. The lamp on the left of ④ RESET button illuminates in green when SG IN to-SG OUT path has been selected.
  • Page 20: Warranty

    9. WARRANTY Services The following terms are applicable to the services provided by the Company to maintain and repair the Unit. Scope The Unit and accessories and options provided by the Company are covered under this section. Technical Service Fee Any repairs provided by the Company during the warranty period will be free of charge in accordance with the Limited Warranty.
  • Page 21 WARRANTY Limited Warranty In the event of failure during the warranty period, the Unit will be repaired or replaced free of charge. Decision of the repair method shall be left at the discretion of the Company. This limited warranty is applicable in Japan only. Scope This warranty is applicable only to the Unit and its accessories.
  • Page 22: Maintenance

    10. MAINTENANCE 1. When repair, maintenance or internal adjustment of the Unit is required, a qualified service engineer takes charge of such work. 2. Maintenance on the user side is restricted to the outside cleaning and functional check of the Unit. 3.
  • Page 23: Noise Laboratory Support Network

    11. NOISE LABORATORY SUPPORT NETWORK If a symptom which seems a trouble is found, inform the model name and serial number of the product together with the symptom to Noise Laboratory or your nearest sales agent of Noise Laboratory. When the product is returned to Noise Laboratory, write the state of the trouble, contents of your request, model name and serial number in a repair order, and pack the product and repair order sheet in the former package of equivalent suitable for transit and send them back.
  • Page 24 NOISE LABORATORY CO., LTD. 1-4-4, Chiyoda, Chuo-ku, Sagamihara City, Kanagawa Pref., 252-0237, Japan TEL: +81-(0)42-712-2051 FAX: +81-(0)42-712-2050 URL: http://www.noiseken.co.jp Printed in Japan...