Monitoring Adaptive Slowdown™ System (U.s. Patent Pending); Floor Adjustment; Car Is Too Low - Smartrise HYDRO:EVOLVED Startup Manual

Hide thumbs Also See for HYDRO:EVOLVED:
Table of Contents

Advertisement

Hydro:Evolved Start-Up Guide
8.3
Monitoring Adaptive Slowdown™ system (U.S. Patent Pending)
The actual slowdown average distances can be monitored by navigating to MAIN MENU |
DEBUG | VIEW DEBUG DATA |, Indexes 070 (UP) and 071 (DN).
These displays are updates at the end of each run. The Up distance average appear under
index 070. The Down distance average appear under index 071.
These distances will increase after TSRD or NTS events.
NOTE: If the distances are not stable, the car may be experiencing NTS alarms at the
terminal landings. Check the Leveling Time distances (Section 7). If the average distances
on the Debug Data screens drop too far below the Leveling Time distances, the system may
trigger NTS alarms. To correct this either decrease the Leveling Time setting (Section 7) or
increase the NTS timeout at MAIN MENU | SAFETY | NTS ODL.
9

Floor Adjustment

If the car does not stop at the exact floor level, tripping can occur. The floor adjustment allows
for adjusting the stopping point of the elevator. The value reflects the change amount and will
return to 0 after the change is saved.
9.1

Car is Too Low

If the car stops before floor level, increase the distance by the amount the car needs to
move up.
Navigate to MAIN MENU | SETUP | FLOORS | TOO HIGH/ TOO LOW.
Jul 14, 2022
©2022 Smartrise Engineering, Inc. All Rights Reserved