  • Page 1 The most technological line of Fiorenzato. Installation, operation and maintenance manual...
  • Page 2: Table Of Contents

    Home page 5.4.2 Disabling/Enabling the automatic weighing system 5.4.2.1 Disabling the automatic weighing system 5.4.2.2 Activation of the automatic weighing system 5.4.3 Settings Menu Fiorenzato | Series_00 Ed. 04/2022 1 / 49 2 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 3: General Information

    The images, data, texts and descriptions included in this documentation are the It is the purchaser’s obligation to provide appropriate training in the property of Fiorenzato M.C. S.r.l. and refl ect the state of the art of the machine at the use and maintenance of the coffee grinder-doser for the personnel time it was placed on the market.
  • Page 4: Warranty

    Series 1.6 Warranty IDENTIFICATION DATA AND TECHNICAL SPECIFICATIONS Fiorenzato M.C. S.r.l. provides a 24-month warranty for its products from the date of 2.1 Introduction the sales invoice issued by Fiorenzato M.C. S.r.l.. Making coffee is an art and in order to master its secrets, you need to follow precise During the warranty period, the manufacturer undertakes to repair or replace, free of rules.
  • Page 5: Identifi Cation Of The Main Parts Of The Grinder-Doser

    2.5 The models in the line and technical specifi cations Fiorenzato M.C. S.r.l. manufactures grinder-dosers in the line in the following Hopper lid models: •...
  • Page 6: Noise Level

    ATTENTION! Before installing, switching on and using the grinder-doser of of a single dose [g] Fiorenzato M.C. S.r.l. for the fi rst time, you must have read and understood Weight (**) single dose [g] all the contents of this documentation and the “SAFETY INSTRUCTIONS”...
  • Page 7: Precautions For Proper And Safe Use

    All grinder-dosers manufactured by Fiorenzato M.C. S.r.l. are equipped with appropriate mechanical and electromechanical devices to protect the safety Reasonably foreseeable misuse includes: of the user and the integrity/functionality of the appliance during use.
  • Page 8: Residual Risks

    Fig. 6 3.5 Residual risks Fiorenzato M.C. S.r.l. has taken all necessary precautions during the design phase to ensure that the grinder-doser can be used under the safest possible conditions. However, during installation, cleaning and maintenance of the appliance, there are still some residual risks that cannot be eliminated.
  • Page 9: Choosing The Installation Location

    The grinder-doser is now powered and ready for use. ATTENTION! Packaging parts must not be left within the reach of children as they are a potential source of danger. Keep the packaging until the warranty expires. Fiorenzato | Series_00 Ed. 04/2022 15 / 49 16 / 49 Fiorenzato | Series_00 Ed.
  • Page 10: Using The Grinder-Doser

    (§5.3) required in order to make the weighing system operational, which is enabled by default when the appliance is fi rst switched on. Fig. 11 Fiorenzato | Series_00 Ed. 04/2022 17 / 49 18 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 11: Initial Start-Up" Procedure

    Tare weight detection the tare weight. • Wait for the “Dispense single dose” command to Do not touch the grinder-doser appear on the display. Fiorenzato | Series_00 Ed. 04/2022 19 / 49 20 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 12: Operator Control Panel

    fi rst switched on. The management software adopted by Fiorenzato for its coffee grinder-dosers is All the functions accessible from the “Settings menu” are described in the following extremely intuitive to use. This user guide will allow you to quickly become familiar with the function buttons and the various setting options on your new appliance.
  • Page 13 “Settings menu” (§ 5.4.3.6). Display fi eld showing only the weight (or time) of grinding set for the triple dose, which can be hidden from the menu. Fiorenzato | Series_00 Ed. 04/2022 23 / 49 24 / 49 Fiorenzato | Series_00 Ed.
  • Page 14: Disabling The Automatic Weighing System

    (see Fig. 12 Part 9). Once the command has Warning icon. It only appears at the end of the time set by Fiorenzato been given, the display will load the menu, allowing you to select the parameter to be to indicate the need to replace the grinding blades (§...
  • Page 15: Dose Weight Display

    If the “Grinding weight display” option is disabled ( ), the dispensing weights are not displayed on the HOME page. HOME page without visible dose weights Fiorenzato | Series_00 Ed. 04/2022 27 / 49 28 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 16: Change Dose Times

    If the “Grinding time display” option is disabled ( ), the dispensing times are not displayed on the HOME page. HOME page without grinding times displayed Fiorenzato | Series_00 Ed. 04/2022 29 / 49 30 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 17: Xgi System

    System” is disabled, the 'Initial start-up' option is not enabled and is displayed in grey. CONFIRM START First page for “Initial start-up” procedure 5.4.3.9 Display brightness Fiorenzato | Series_00 Ed. 04/2022 31 / 49 32 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 18: Screensaver

    Greek • Spanish blade drive motor). Croatian • Portuguese • Greek Arabic • Croatian Chinese • Arabic • Chinese Korean • Korean Language selection Fiorenzato | Series_00 Ed. 04/2022 33 / 49 34 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 19: Resetting Dose Weights

    - enable custom logo - total reset of statistics - grinding blade counters - initialisation - scales calibration - scales check Fiorenzato | Series_00 Ed. 04/2022 35 / 49 36 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 20: Adjusting The Degree Of Grinding

    Fiorenzato | Series_00 Ed. 04/2022 37 / 49 38 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 21: Grinder-Doser Maintenance

    All routine maintenance for your appliance is summarised in the table below. washed in a dishwasher. Fiorenzato M.C. S.r.l. recommends that customers strictly follow the instructions given and carry them out within the stated times and as described. •...
  • Page 22: Checking The Power Cable Status

    ATTENTION! It is forbidden to use water or steam jets to clean the machine body. ATTENTION! If the power cable is damaged, replace it with one of the same type. Fiorenzato | Series_00 Ed. 04/2022 41 / 49 42 / 49 Fiorenzato | Series_00 Ed.
  • Page 23: Thoroughly Cleaning The Grinding Blades

    Thoroughly cleaning the grinding blades 6.1.5 Replacing the grinding blades The scheduled deadline for replacing the grinding blades is set by Fiorenzato M.C. S.r.l. EVERY MONTH: thoroughly clean the grinding blades depending on the type of grinders and the grinder-doser model.
  • Page 24: Anomalies - Causes - Remedies

    (Green scales). (Green scales). Fiorenzato | Series_00 Ed. 04/2022 45 / 49 46 / 49 Fiorenzato | Series_00 Ed. 04/2022...
  • Page 25 The icon The grinding blades • The grinder-doser can be used whether to contact the Fiorenzato M.C. S.r.l. service department or have are close to the until the set time limit is reached. “ ”...
  • Page 26: Requesting Spare Parts

    Select the necessary spare parts using the exploded view tables of the product on the portal. • Follow the guided procedure to complete their order and send it to Fiorenzato M.C. S.r.l.. • The local distributor will be contacted by personnel of Fiorenzato M.C. S.r.l., who will take care of the request.