Replacing Load Cell - Jadever JWE-3K Service Manual

Table of Contents

Advertisement

JADEVER
STEP ONE
STEP THREE

3-2 Replacing load cell

1.
Refer to the three figures below.
2.
Follow the steps 1 to 6 in the previous Section to remove the load cell wires.
3.
Rotate with hands the two rear support feet on the bottom of the scale to dismount them.
4.
Loosen and remove the four screws that fix the load cell lower supporter to the scale
lower cover.
5.
Lift the whole load cell supporter module out of the scale.
6.
On the load cell supporter module, loosen and remove the four hexagonal socket screws,
two respectively on the upper and lower supporter, for taking the load cell out.
As per the right of proprietary intellectual property, may not be reproduced in any form without written permission.
JCE/JWE
STEP TWO
Service Manual - V05
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jwe-6kJwe-15kJwe-30kJce-3kJce-6kJce-15k ... Show all

Table of Contents