SMC Networks SJ3000A Manual page 79

4-port solenoid valve cassette type manifold rubber seal

Advertisement

EX510 Gateway Type Serial Transmission System
Standard
With switch
Individual wiring
[For plug-in mixed mounting]
∗1 Refer to pages 95 and 96 for the
dedicated non plug-in individual wiring.
q
w
Series
Type of actuation
1
1
SJ1000
2-position single solenoid
2
2
SJ2000
2-position double solenoid
3
3
SJ3000
3-position closed center
4
3-position exhaust center
5
3-position pressure center
∗ Refer to pages 18 to 21 for the symbol.
∗ The large flow type ("A") is available only for actuation types "1" and "2."
e
r
Pilot type
Nil
Nil
Standard flow type
A
R
1
Large flow type
∗1 SJ3000 series only
∗ The external pilot specification
is not applicable for 4-position
dual 3-port valves.
o
Connector entry
C
:
Dedicated for
centralized wiring
Symbol
SJ1000
V
SJ2000
V
SJ3000
V
∗ Connector entries with the symbol "Mm" cannot use the switch signal from the common wiring on the
manifold. For details, refer to the "Connector Wiring Diagram" on page 17.
∗ When ordering a connector separately, refer to pages 144 and 145.
!2
Manual override
Symbol/Specification
SJ1000 SJ2000 SJ3000(A)
Nil
:
Non-locking
push type
V
D
:
Push-turn locking
slotted type
V
F
:
Slide locking type
Plug-in
Connector Type
How to Order Solenoid Valves
SJ 3 1 60
SJ 3
1 60
SJ 3 1 60
1
q
w
A
Dual 3-port valve: N.C./N.C.
B
Dual 3-port valve: N.O./N.O.
C
Dual 3-port valve: N.C./N.O.
t
Back pressure check valve
Nil
Internal pilot
K
External pilot
∗ 3-position and large flow type ("A")
solenoid valves cannot be equipped
with a back pressure check valve.
M
MN
:
:
Individual wiring, With lead wire
Individual wiring,
Length: 300 mm
Without lead wire
With linkage-printed
With linkage-printed
circuit board
circuit board
V
V
V
V
!3
A, B port size
Metric/One-touch fitting
Symbol A, B port SJ1000 SJ2000 SJ3000 SJ3000A
C2
ø2
V
C4
ø4
V
V
V
C6
ø6
L2
ø2
L4
ø4
L6
ø6
V
V
B2
ø2
B4
ø4
B6
ø6
Thread piping
Symbol A, B port SJ1000 SJ2000 SJ3000 SJ3000A
V
V
M3
M3 x 0.5 —
M5
M5 x 0.8 —
SJ1000/2000/3000
5
5
5
e r
t
y
u
y
Coil type
Symbol
Nil
With power-saving circuit
T
∗ Be sure to select the power-saving circuit type if the valve is to
be continuously energized for long periods of time.
∗ For the SJ1000 series, only the power-saving circuit type is available.
u
Rated voltage
5
None
24 VDC
Built-in
MO
:
Individual wiring,
Without connector
With linkage-printed
circuit board
V
V
Inch/One-touch fitting
Symbol
N1
V
V
N3
V
V
V
N7
V
V
LN1
V
V
LN3
V
V
V
LN7
V
V
BN1
V
V
BN3
V
V
V
BN7
V
V
!4
V
V
V
C
U
C6
C Z
J
C6
M
Z
C6
i
o !0
!1
!2
Coil type
SJ1000
SJ2000 SJ3000(A)
Standard
V
(Continuous duty type)
i
Common specification
Nil
Positive common
N
Negative common
∗ Leave blank for the non-polar type.
∗ When the standard valve and valve with a switch are used, select a
common specification that matches the SI unit common specification.
!0
Light/surge voltage suppressor
Symbol
Specification
With light/surge voltage
U
suppressor (Non-polar type)
With light/surge voltage
Z
suppressor (Polar type)
∗ When the type with a power-saving circuit, with a switch, or with
individual wiring is used, the non-polar type cannot be selected.
∗ Select "CU" or "CZ" for the valve when the SI unit output polarity is Nil (positive common).
Select "CU" or "NCZ" for the valve when the SI unit output polarity is N (negative common).
!1
With switch
SJ1000
SJ2000 SJ3000(A)
A, B port
SJ1000 SJ2000 SJ3000 SJ3000A
ø1/8"
V
V
ø5/32"
V
V
ø1/4"
V
ø1/8"
V
V
ø5/32"
V
V
ø1/4"
V
ø1/8"
V
V
ø5/32"
V
V
ø1/4"
V
∗ Leave blank for 2-position
Single solenoid
double, 3-position, and
wiring specification
4-position solenoid valves.
Select "D" only when setting
Nil
Single wiring
a blank number for wiring.
D
Double wiring
Refer to page 16 for details.
Protective class
class
Series
SJ
1000
2000
3000
4000
!3
!4
V
V
V
V
SJ1000 SJ2000 SJ3000(A)
V
V
V
V
V
V
V
SJ3A6
V
V
V
V
V
V
( Mark:
)
#
78