4-port solenoid valve cassette type manifold rubber seal

Advertisement

SJ1000/2000/3000/4000
Manifold Electrical Wiring: Connector Type (Non-polar Type)
Type 60F: D-sub connector (25 pins)
13
Common
SOL.b
12
25
SOL.a
SOL.b
11
24
SOL.a
SOL.b
15
SOL.a
2
SOL.b
14
SOL.a
1
∗ This circuit is for the specifications with up to 12
stations of 2-position double, 3-position, and
4-position dual 3-port valves. There should be
wired in order 1→14→2→15 without skipping or
leaving any connectors remaining.
Type 60PH: Flat ribbon cable (10 pins)
10
Common
9
SOL.b
8
SOL.a
7
SOL.b
4
SOL.a
3
SOL.b
2
SOL.a
1
Triangle mark
∗ This circuit is for the specifications with up to 4
stations of 2-position double, 3-position, and
4-position dual 3-port valves. There should be
wired in order 1→2→3→4 without skipping or
leaving any connectors remaining.
Caution
When the non-polar U type valves are used, either positive common or negative common wiring of the manifold is possible. However, when the Z type valves
are used, select the positive common or negative common according to the wiring specifications.
35
Type 60P: Flat ribbon cable (26 pins)
26
24
Station 12
22
Station 11
Station 2
4
Station 1
2
∗ This circuit is for the specifications with up to 12
stations of 2-position double, 3-position, and
4-position dual 3-port valves. There should be
wired in order 1→2→3→4 without skipping or
leaving any connectors remaining.
Station 4
Station 2
Station 1
Series
Common
25
SOL.b
Station 12
SOL.a
23
SOL.b
Station 11
SOL.a
21
SOL.b
Station 2
SOL.a
3
SOL.b
Station 1
SOL.a
1
Triangle mark
Type 60PG: Flat ribbon cable (20 pins)
20
Common
19
SOL.b
18
SOL.a
17
SOL.b
16
SOL.a
15
SOL.b
4
SOL.a
3
SOL.b
2
SOL.a
1
Triangle mark
∗ This circuit is for the specifications with up to 9
stations of 2-position double, 3-position, and
4-position dual 3-port valves. There should be
wired in order 1→2→3→4 without skipping or
leaving any connectors remaining.
Station 9
Station 8
Station 2
Station 1

Advertisement