Mitsubishi Electric MELSEC iQ-R MES Series User Manual page 40

Interface module
Hide thumbs Also See for MELSEC iQ-R MES Series:
Table of Contents

Advertisement

Setting a job in which only continuous array tags are used and operating an
RD81MES96N
When setting any of the following jobs in which only continuous array tags are used and operating an RD81MES96N, the
device memory is accessed in device tag component units.
 Page 38 Job setting 1, Page 38 Job setting 2, Page 38 Job setting 3
The following table shows the access units when setting any of the jobs shown in the above sections and operating an
RD81MES96N.
Access target device type (series)
RCPU
Programmable
controller CPU
Process CPU
C Controller module
*1
QCPU (Q mode)
LCPU
FX5CPU
FXCPU
*1 Access units differ depending on the module type. When data inconsistency is a problem, select "Single Handshake" or "Multiple
Handshake" for a trigger condition.
*2 For access without using an Ethernet port of an RD81MES96N
*3 For access by using an Ethernet port of an RD81MES96N
Precautions
When accessing the device memory in device tag component units, device values may be obtained from multiple sequence
scans and applied, which may cause data inconsistency.
When data inconsistency is a problem, refer to the following:
Page 39 When data inconsistency is a problem
■Job setting 1
Action
Operation action (substitution)
■Job setting 2
Action
DB communication action (Multiple
Select)
Operation action (substitution)
■Job setting 3
Action
DB communication action (Multiple
Select)
Operation action (substitution)
2 SPECIFICATIONS
38
2.2 Access Specifications for a CPU Module
Device reading
General access
960 points
480 points
*2
32 points
*3
64 points
Details
Either of the following conditions is satisfied.
• All device tag components are devices other than bit devices.
• The array sizes of all device tag components are multiples of 16.
Details
All device tag components are devices other than bit devices.
Either of the following conditions is satisfied.
• All device tag components are devices other than bit devices.
• The array sizes of all device tag components are multiples of 16.
Details
All of the following conditions are satisfied.
• All device tag components are bit devices.
• The array sizes of all device tag components are multiples of 16.
• The checkbox of "Clear the unsubstituted assignment data to 0" is selected for "Operation Setting at the No. of
Selected Records Insufficient".
Either of the following conditions is satisfied.
• All device tag components are devices other than bit devices.
• The array sizes of all device tag components are multiples of 16.
High-speed access
8192 points
Not supported.
Device writing
949 points
480 points
469 points
*2
32 points
*3
64 points

Advertisement

Table of Contents
loading

Table of Contents