PART A: Basic machine
Granulator
H 80 Series
4.9.2

Safety device for the granulator housing

Illustration:
Safety device upper
housing
(1) Safety switch for
housing
(2) Safety switch for
screen
 VIRTUS 2023, All rights reserved
2
The granulator upper section can be opened by means of a
hydraulic system. After switching off the machine a time relay will
be activated this prevents that the hydraulic system can be started
before the rotor has come to a complete standstill.
Another safety switch is installed on the hinge of the granulator.
This prevents the granulator being put into operation when the
granulator upper section is opened.
A third safety switch is installed on the hinge of the screen holder.
It prevents that the granulator can be started, when the screen
holder is lowered.
1
Page 23