Gas Specifications; Preparation; Gaslineinstallation - Majestic VERMONT Castings RFSDV34 Installation Instructions & Homeowner's Manual

Freestanding direct vent fireplace
Table of Contents

Advertisement

$...;~,~·~,,
1:;,<{.',,_,.,,,...;;,.~'i''-..
,-.,-,;·,~
,-~: .. ~·,;,,,··•·'-,,,~'..:--'
'ci;·?:: ·:·
:~'.\;\i
GA:SSPECIFICATIONS
:+·:,,,:,;•'!/ ,·.·
1.t..;t _?;, ~· • :\,
·t:
<
1 "
-.,•~.
__
"'".v
- :, , -,. ~._ ;, ,,. ( •.
:c ::::: ,:-· ·w~~-,..:: -.
.
MAX.
MIN.
INPUT
INPUT
MQlill.
l:l[EL
Qt,S!:;Ql,!TRQL
!UJIB
lUl.lli.
RFSDV34RN
Natural Gas
Millivolt Hi/Lo
30,000
21,000
RFSDV34RP
Propane Gas
Millivolt Hi/Lo
30,000
22,500
RFSDV34TN
Natural Gas
Thermostatic
30,000
21,000
RFSDV34TP
Propane Gas
Thermostatic
30,000
22,S00
RFSDV34RFN
Natural Gas
Radio Frequency
30,000
21,000
RFSDV34RFP
Propane Gas
Radio Frequency
30,000
22,500
RFSDV34RMH
Nat/Prop
Millivolt Hi/Lo
30,000
21,000
This appliance may be installed in an aftermarket per-
manently located, manufactured (mobile) home, where
not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is available and used.
The
installation of your l\1ajestic~irep]ace must
'conform with local codes, or in the .absence of
local codes, with National Fuel Gas Code, ANSI
Z223.1 latest edition, or CAN 1 Bl-149.1 aud
.2 Installation Code. (EXCEPTION: Do not
. derate this appliance for elevations up to 4,500
.. ft. (1,390m). l\1aintaiu the manifold pressure at
.. 3.5 inches W.C. 'for Natural Gas and 10 inches
W.C. for LP gas.).
RFSDV34
CERTIFIED TO
ANSI.Z21.88b-1999 / CSA 2.33b - M99 •·)
Vented
Gas
Fireplace Heaters
• )(
',
GAS INLET
&
MANIFOLD PRESSURES
NATURAL
LP (Propane)
Inlet Minimum
4.5" we
11.0" we
Inlet Maximum
7.0"
WC
10.0"
WC
Manifold Pressure
3.5"
WC
10.0"
WC
A
The use of wall paper adjacent to this fireplace
is not recommended, as the high heat given off
by this fireplace may adversely effect the bind-
ers in the adhesive 11sed to apply the wallpaper.
Before beginning, remove the glass door from the fireplace.
Also check to make sure there is no hidden damage to the
fireplace. Take a minute and plan out the gas, vent and electri-
cal supply. See Glass Removal Section.
,
GASLINEINSTALLATION , .
. '
'
'
.
.
'
-
A
When purgillg the gas line, the front glass m11st
be removed.
The gas pipeline can be brought in through the rear of the
fireplace as well as the bottom.
Knockouts are provided
on the bottom behind the valve to allow for the gas pipe
installation and testing of any gas connection.
It is most
convenient to bring the gas line in from the rear right side of
the valve, as this allows fan installation or removal without
disconnecting the gas line.
The gas line connection can be made with
A
properly tinned 3/8" copper tubing, 3/8" rigid
pipe or a11 approved flex connector. Since
some municipalities have some additional local
codes, it is always best to consult your local
authority and the CANICGA- Bl49 (.1 or .2)
installation code,
FOR U,S-A Installations consult the current National Fuel
Gas Code, ANSI 2223.1
A
Always check for gas leaks with a mild soap
and water solution. Do ltot 11se an open flame
for leak testing.
The gas control is equipped with a captured
screw type pressure test point, therefore it is
not necessary to provide a 1/8" test point up
stream of the control.
Fig. 2
10001948/1 -Page 5 -

Advertisement

Table of Contents
loading

Table of Contents