PRE-INSTALLATION INFORMATION
HIGH ELEVATIONS
Input ratings are shown in BTU per hour and are certified without deration for elevations up to
4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, installation must be in accordance with the cur-
rent ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local authorities having jurisdiciton for installation at
elevations above 4,500 feet (1,370 m).
ORIFICE SIZES, PRESSURES AND BTUs
NATURAL GAS
Manifold Press: (w.c.)
Maximum Supply Pressure
Minimum Supply Pressure

GAS SPECIFICATIONS

Model
Fuel
BV4536NV
Natural
BV4536PV
Propane/LP
BV4536NE
Natural
BV4536PE
Propane/LP Electronic
BV5142NV
Natural
BV5142PV
Propane/LP
BV5142NE
Natural
BV5142PE
Propane/LP Electronic
BEFORE YOU START
Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for
shipping damage and immediately inform your dealer if any damage is found. Do not install any unit
with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts
have been received. You should have the following:
• Fireplace (Firebox and Burner System)
• Log Set
• Lava Rock
ITEMS REQUIRED FOR INSTALLATION
Tools:
• Phillips screwdriver
• Hammer
• Saw and/or saber saw
• Level
• Measuring tape
• Electric drill and bits
• Pliers
• Square
• Pipe Wrench
41D2001
PROPANE GAS
3.5"
Manifold Press: (w.c.)
10.5"
Maximum Supply Pressure
4.0"
Minimum Supply Pressure
Max.
Gas
Input
Control
BTU/h
Millivolt
50,000
Millivolt
50,000
Electronic
50,000
50,000
Millivolt
50,000
Millivolt
50,000
Electronic
50,000
50,000
• Rock Wool
• Exterior outside air hood
• Bifold glass doors in a separate package (LPG only)
Building Supplies:
• Framing materials
• Wall finishing materials
• Caulking material (noncombustible)
• Fireplace surround material (noncombustible)
• Piping complying with Local Codes
• Tee joint
• Pipe sealant approved for use with Propane/LP gas
(resistant to sulfur compounds)
• 4" Flexible liner or equivalent
BV4536, BV5142 Natural Vent Gas Fireplace
10"
13"
11"