Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
IMPORTANT: Read all instructions
and warnings carefully before starting
f i r e - p a r t s . c o m
installation. Failure to follow these in-
structions may result in a possible fire
hazard and will void the warranty.
WARNING: If the information in this
manual is not followed exactly, a fire
or explosion may result causing prop-
erty damage, personal injury or loss of
life.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier. Do not
store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
1. Open windows
2. Do not touch electrical switches.
3. Do not try to light any appliance.
4. Extinguish any open flame.
5. Do not use the phone in your build-
ing.
6. Immediately call your gas supplier
from a neighbor's phone.
7. Follow your gas supplier's instruc-
tions.
8. If you cannot reach your gas sup-
plier, call the fire department.
Decorative Gas Appliances
Models: NVBR36, NVBC36
NVBR42, NVBC42
Homeowner's Installation and
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
NVBR36
NVBC42
Operating Manual
950
NVB cover 2/1/01
C E RT I F I E D
7412950 8/06 Rev. 15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NVBR36 and is the answer not in the manual?

Questions and answers

Summary of Contents for Majestic NVBR36

  • Page 1 Decorative Gas Appliances Models: NVBR36, NVBC36 NVBR42, NVBC42 INSTALLER/CONSUMER SAFETY INFORMATION NVBR36 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting f i r e - p a r t s . c o m installation.
  • Page 2: Table Of Contents

    NVB Series B-Vent Gas Fireplace Table of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: General Information

    NVB Series B-Vent Gas Fireplace General Information This gas appliance should be installed by a qualified Description installer in accordance with local building codes and with current CSA-B149.1 Installation codes for Gas Burning NVB Series are radiant or heat circulating, natural draft Appliances and Equipment.
  • Page 4 - p a r t s . c o m �����" 3" 3" 40" (337mm) ����" (76mm) (76mm) (1016mm) (165mm) FP561 Fig. 1 NVBR36 Series specification and framing dimensions. NVBC36 Series Gas Appliance — Circulating Model WF561 NVBR36 11/11/97 ��" (559mm) Rough Opening Depth 45���" (1162mm) 6" DIA. ����"...
  • Page 5 NVB Series B-Vent Gas Fireplace NVBR42 Series Gas Appliance ��" (711mm) Rough Opening Depth 49" (1245mm) 6" DIA. ���" (13mm) ����" (213mm) �����" (521mm) 20" (508mm) Recessed ���" (16mm) Nailing Flange 35���" (895mm) Rough Opening Width 47" (1194mm) Rough Opening Height ���"...
  • Page 6: Clearance To Combustibles

    NVB Series B-Vent Gas Fireplace Clearance to Combustibles Appliances Top ............0” (0 mm) Bottom .............0” (0 mm) Side ............0” (0 mm) Back ............0” (0 mm) Perpendicular Sidewall ......0” (0 mm) Top of unit to ceiling ......36” (914 mm) Front of unit to combustibles .....36” (914 mm) Black Sur- Mantel round Face...
  • Page 7: Framing & Finishing

    14.0” w.c. Manifold Pressure 3.5”w.c. 10.0” w.c. Fig. 6 Adjustable drywall strip (nailing flange). Finishing NVBR36 / NVBC36 / NVBC42 / NVBR42 FP549 9/29/97 Certified to CAUTION: All joints between the finished BR/BC wall and the appliance surround (top and ANSI Z21.50b-2002 / CSA 2.22b-2002...
  • Page 8: Parts Identification And Chase Installation

    NVB Series B-Vent Gas Fireplace Parts Identification and Chase Installation (Insulation methods shown are optional for cold climate, not a requirement for unit operation.) Termination Cap Storm Collar Pan Flashing Batt Insulation (cut out around firestop) Draftstop Firestop Ceiling Level *Do not install header until unit is in place.
  • Page 9: Remote Wall Switch

    NVB Series B-Vent Gas Fireplace U.S.: Consult the current National Fuel Gas Code, R Models ANSI Z223.1/NFPA 54. Canada: CSA - B149.1 installation code. Test for leaks. Use a 50/50 solution of liquid soap and Pilot water to test for leaks at gas fittings and joints. Apply water/soap solution with brush only - do not over apply.
  • Page 10: Eb-1 Electrical Box

    NVB Series B-Vent Gas Fireplace Install the Venting System, EB-1 Electrical Box Flashing and Termination The fireplace, when installed, must be elec- trically connected and grounded in accor- See venting installation instructions provided by the B- dance with local codes or, in the absence Vent manufacturer.
  • Page 11: Venting Runs

    NVB Series B-Vent Gas Fireplace Venting Runs Horizontal Run (in feet) 10 12 14 16 18 20 Horizontal Run (in feet) �������������������������������� ������������ �� �� �� �� �� �� �� �� �� �� �� �� �� �� FP567a �� Venting Run = Acceptable venting configuration Graph = Acceptable venting configuration...
  • Page 12: Operating Instructions

    NVB Series B-Vent Gas Fireplace Operating Instructions Glass Information Glass Cleaning Only glass approved for use in Majestic It will be necessary to clean the glass periodically. Fireplaces products may be used for re- During start-up, condensation, which is normal, forms placement.
  • Page 13: First Firing

    NVB Series B-Vent Gas Fireplace Flame Characteristics Middle Cross It is important to periodically perform a visual Right Cross check of the pilot and the burner flames. Compare them to the illustrations below (Figs. 18, 19, 20). If any of the flames ap- Left Cross pear abnormal call a service person.
  • Page 14 NVB Series B-Vent Gas Fireplace Embers Red Glow LG151 Fig. 19 NVB36 flame appearance. f i r e - p a r t s . c o m LG151 NVB36 log flames 2/2/01 djt LG150 Fig. 20 NVB42 flame appearance. LG150 NVB42 log flames...
  • Page 15: Lighting & Operating Instructions

    NVB Series B-Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- •...
  • Page 16 NVB Series B-Vent Gas Fireplace Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life. FOR YOUR SAFETY READ THE FOLLOWING WARNINGS BEFORE LIGHTING THE APPLIANCE Follow the gas suppliers instructions.
  • Page 17: Troubleshooting

    NVB Series B-Vent Gas Fireplace Troubleshooting Nova SIT 820 Standing Pilot START CHECK • Supply Line Hooked up Gas Supply On • Shutoff Valve Open • Lockout has engaged. Wait 60 seconds and try again. • Piezo not tight enough for good ground.
  • Page 18 NVB Series B-Vent Gas Fireplace Troubleshooting NOVA SIT 822 with Honeywell S8600 B Electronic Ignition Remove glass panel before servicing. START CHECK : • Line Voltage (120VAC) • Turn gas supply off • Low Voltage Transformer • Turn ON/OFF Switch (19.5 minimum VAC) to call for heat.
  • Page 19: Maintenance

    NVB Series B-Vent Gas Fireplace Maintenance In order to properly clean the burner and pilot assem- Burner and Burner Compartment bly, turn off the gas to the unit, open the glass door It is important to keep the burner and the burner (if used), remove logs exposing the burner and pilot compartment clean.
  • Page 20: Replacement Parts

    NVB Series B-Vent Gas Fireplace 1. NVB36 Logs 1. NVB42 Logs 6a/b 28a/b 19a/b 21a/b f i r e - p a r t s . c o m 29a/b MVPV SENSE SPARK (BURNER) 23a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
  • Page 21 Parts may be ordered through your Model and serial numbers are listed on the rat- Majestic Fireplaces distributor or dealer. ing plate (located on right side of combustion You will need the following information when ordering replacement chamber).
  • Page 22: Optional Accessories

    Bi-fold and single panel glass doors are available to NVB—TVD6/7 “ON/OFF” 11/17/97 enhance the viewing of the fireplace. “ON/OFF” and Temperature Appliance Models Glass Doors Shrouds NVBR36/NVBC36 36GSKBB 36GDKBB Decorative shrouds are available to enhance the ap- 36GDKBK pearance of the termination cap. 36GDKDP Square Shroud SLSBL...
  • Page 23: Warranty

    LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY •...
  • Page 24 f i r e - p a r t s . c o m CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

Nvbc36Nvbr42Nvbc42

Table of Contents

Save PDF