MEASURING EXHAUST GASES
11
After countdown is finished & your analyzer is ready to use, put your
exhaust probe into the engine exhaust.
For normal emission testing, ensure engine is at normal operating
temperature.
Engine conditions must be constant to give stable measurements.
Ensure probe is fully inserted in exhaust pipe to avoid exhaust dilution with
back-flushing ambient air.
Position hose assembly away from hot surfaces.
SAFETY WARNING
Use suitable protection when disconnecting probe which may be hot!
Do not exceed analyzer operating specifications - In particular:
Do not exceed analyzer internal temperature operating range
•
Do not put analyzer on hot surfaces
•
Do not exceed analyzer water trap max levels
•
Do not let analyzer particle filter become dirty and blocked
•
Check readings are stable & within expected range.
28 KANE-EGA4/5 MANUAL