Viking E-1600A-TP-EWP Technical Practice page 3

Ada emergency phones for talk-a-phone applications
Hide thumbs Also See for E-1600A-TP-EWP:
Table of Contents

Advertisement

B. Mounting
11.75
A. DIP Switches
Description
Sw 3
Sw 1
Ring Indication Only.
OFF
ON
Off-Hook/Loop Current Detection Only.
ON
OFF
Ring and Off-Hook/Loop Current Detection.
ON
ON
Ring Cadence Mode (see section B)
Sw 2
Ring Cadence Mode ON - strobe remains activated in between rings.
ON
Ring Cadence Mode OFF - strobe is activated only during ringing.
OFF
1. Ring Indication Only
Place DIP switch 2 on the 1600A emergency phone board in the OFF position (not shown in the diagram - see
1600A Emergency Phone Board Programming section J).
emergency phone board will not answer an incoming call. The LDB-3 control module can monitor for ring-
ing any place along the ringing line. Place DIP switch 1 ON and DIP switch 3 OFF.
2. Loop/Off-hook Indication Only
Place DIP switch 1 OFF and DIP switch 3 ON. In this configuration, the E-1600-BLT will only flash the strobe light
while off-hook (while the emergency phone is in use).
3. Both Ring and Loop/Off-hook Indication
If the application requires ring and loop/off-hook indication, place DIP switch 1 and 3 in the ON position.
B. Ring Cadence Mode
DIP switch 2 is used for switching between different ring detection modes. In the OFF position, the strobe light and
relay will activate only while ring voltage is present and will turn off between rings. In the ON position, the strobe light
and relay will remain on for up to 5.75 seconds after the ringing has stopped. This allows the strobe light and relay to
remain on between rings of a standard ring cadence.
enabled (DIP switch
C. Relay Contacts
Normally open and normally closed relay contacts are available on the orange, purple and yellow wires. The contacts
are rated at .5A @ 125VAC/1A @ 30VDC. If contacts are driving an inductive load, place a suppression device at the
load to snub high voltage spikes.
0.75
4.50
EMERGENCY
5.125
Typ
10.250
5.125
2.125
0.75
2.75
-
).
9.50
7.750
PHONE
CALL
MODEL E-1600A-TP
CONNECTED
PUSH FOR
HELP
VIKING
©
4.00
2.75
To use the Ring Cadence Mode, ring detection MUST be
Minimum Cutout
"Call Connected" LED
Push for "Help" Button ("Info" Button
available on model E-1600A-TP2-EWP)
Grade 2 Braille Label
(6) 0.250 diameter counter sunk 82° x 0.410
diameter holes for flathead #10 x 24
tamper-proof screws (not included)
OFF
ON
1
2
3
1
2
3
With DIP switch
in the
4
5
6
7
8
9
10
11
position, the
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-1600a-tp2-ewp