5-1. Connection and Menu Setting
Signal Generator
Component Y
Component PB
Component PR
BB (or Composite)
Composite
Y/C
To oscilloscope for trigger
<Caution>
Set the component output level of signal generator to b CAM level.
Set the SET-UP MENU as follows.
600: PB/PR IN LV
620: PB/PR OUT LV
613: SETUP (Select this item and Press the "STOP" button, then open the SETUP menu as follows.)
00: CMPST IN THRU
01: CMPST OUT
02: CMPNT IN THRU
03: CMPNT OUT
AJ-D455P
Y IN
PB IN
PR IN
REF IN
(Termination
ON)
VIDEO IN
(Termination
OFF)
S-VIDEO IN
b CAM
b CAM
THRU
THRU
Select
Y OUT
PB OUT
PR OUT
VIDEO1 OUT
VIDEO2 OUT
VIDEO3 OUT
ELE-19
Wave Form
Monitor
Ch A1
(Termination ON)
Ch A2
(Termination ON)
Ch A3
(Termination ON)
Ch A
(Termination ON)
Ch B
(Termination ON)
Monitor TV