Maintenance; Maintenance Schedule - Panasonic DVCPRO AJ-D455P Service Manual

Digital video cassette recorder/ component serial interface board/ digital video interface board/ cassette adapter
Hide thumbs Also See for DVCPRO AJ-D455P:
Table of Contents

Advertisement

4. Maintenance

4-1. Maintenance Schedule

Maintenance is done by periodically performing suitable maintenance servicing in order to maintain the functions
always in the best condition, so that the user can use the equipment safely. Video equipment with mounted
mechanisms uses wear parts, and their wear and deterioration causes troubles. Dust and dirt also can impair stable
operation. For this reason it is important not to just perform repair at the time of trouble, but also to perform suitable
maintenance at regular intervals.
Part name
Cleaning of the travel system
-
-
Mechanical chassis unit
1
Cylinder Unit
2
Pinch Arm Unit
3
Cleaning Arm Unit
4
S-Reel Moter Unit
5
T-Reel Moter Unit
6 Thrust Screw Unit
7
Mode SW Unit
8 S1 Loading Arm Unit
9 T1 Boat Unit
10 S5 Post Base Unit
11 Tension Arm Unit
12 A/C Head
13 Loading Motor (1) Arm Unit
14 Reel Drive Motor Unit
15 Pinch Solenoid
16 S Brake Solenoid
17 T Brake Solenoid
18 Distinction SW Unit
19 Cleaner Solenoid
20 Main Cam Gear
21 M Stopper Brake Solenoid
22 Front-loading unit
23 Front Loading Motor
24 Fan motor
Replacement of the mechanical chassis unit is recommended for the 12,000 h maintenance.
C : Perform cleaning.
R : Assembly subject to exchange.
Y : The timing of replacement with Cleaning Arm Unit, either
1000 hours or 1 year as timing come earlier.
G : At the time of exchange, wipe off the old grease and apply
new grease. (Morlytone grease)
L
: Lubrication is necessary.
IM : Included in the mechanical chassis unit.
When the mechanical chassis unit is not exchanged, exchange as
a single part is required.
F
: Included in the front-loading unit.
Part No.
Every 1000
-----
VXY1631Z1
VEG1498
VXL2835
VXL2748
R, Y
VEM0686
VEM0687
VXQ0556
VES0929
VXL2709
VMD2533
VXA6052
VXL2831
VED0419
VEM0645
VEM0585
VSJ0227
VSJ0216
VSJ0216
VXA6199
VSJ0226
VDG1168
VSJ0216
VXA6070
VXA5597
L6FALEFH0007
INF-6
Hours of use (unit: hours)
3000
6000
C: Every 500 hours
R
R
R, G
R, G
R, Y
R, Y
R
R
R, L
R
Exchange after every 10,000 h of energization
<Note:>
The Hours of use indicates the cylinder
rotation time (DRUM RUN).
The maintenance execution time shown in
the chart is recommendation for standard
maintenance execution. This is not the life
of the various parts. The life is influenced
by temperature, humidity, dust, etc.
Please refer to the most recent execution
outline, as the maintenance specifications
and the part numbers may change.
9000
12,000
R
R
IM
R, G
IM
R, Y
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
IM
R
F