IR Series Infrared Lights
(Over 1000-nm Type)
TH2 Series
Instruction Guide
Thank you for purchasing a CCS product. To ensure proper use of the product,
please read this instruction guide before use and keep it for your future reference.
1
Important Information for Equipment Safety
These products have been designed with full consideration of safety. However,
incorrect usage of the products may result in fire, electric shock, or other serious
damages. Please ensure to follow the conditions below.
The following symbols are used in this instruction guide to indicate and
classify the relative importance of warnings and cautions.
I n di c ate s t h at i nc o r r e c t
Warning
usage may result in serious
injury or death.
The following symbols in the Instruction Guide indicate and classify the precautions.
PROHIBITED
DISASSEMBLY
DO NOT TOUCH
DO NOT SUBJECT
PROHIBITED
WITH WET HANDS
TO MOISTURE
These symbols indicate prohibited actions.
Do not disassemble or modify the
Light Unit. Doing so may result in
fire or electric shock.
Do not touch the Light Unit with
wet hands. Doing so may result in
electric shock.
Make sure that the Light Unit is free
of moisture or any liquid. Exposure
to water may result in fire, electric
shock.
If abnormal condition occurs such
as fuming, heat, smell, noise, or
so on, stop using the Light Unit
immediately, and turn off the power
source. A fire or electric shock may
result if the Light Unit is kept used.
Do not use user-made cables. Doing
so may cause product failure. Use the
CCS extension cable if it is necessary
to extend the distance between the
Light Unit and the Control Unit.
Be careful of static electricity.
Damage to the LED Light may
occur, if a person charged with
static electricity touches it. Keep
the product away from all items
charged with static electricity.
D o n o t d r o p t h e L i g h t U n i t o r
subject it to impact. Doing so may
cause the Light Unit to malfunction.
Do not use the Light Unit in the following situations.
Under conditions or in an environment not described in this instruction guide.
In nuclear energy control systems, railroad systems, aviation systems, vehicles,
combustion equipment, medical equipment, amusement machines, or safety equipment.
In applications involving serious risk to life or property, particularly applications
demanding a high level of safety.
Please install the Light Unit to locations with following conditions.
Incorrect installation location may cause Light Unit failure.
In a flat and stable location with
minimal vibration.
Well-ventilated places with minimal dust.
Places that are not subject to sudden
temperature changes.
LED Light for Machine Vision
a n d I n d u s t r i a l I n s p e c t i o n
- Read Before Use -
Indic ates that inc or rect
Caution
usage may result in injury
or property damage.
- Read Before Use -
MANDATORY
ACTIONS
This symbol indicates required actions.
Warning
LED Light radiation may c ause
corneal or retinal abnormalities
if you look directly at the light. To
DISASSEMBLY
prevent harmful light exposure,
PROHIBITED
never look directly at the LED Light.
T h i s L i g h t U n i t g e n e r a t e s h i g h
temperatures. Do not touch the Light
Unit while it is turned on or immediately
after it is turned off, or burning may
DO NOT TOUCH
WITH WET HANDS
result. Provide cooling with a fan or
other ventilation if the Light Unit is to
be used in a closed space.
Connect or disconnect the light
cable only after turning off the
power source. Failure to do so
may result in circuit damage, fire
DO NOT SUBJECT
TO MOISTURE
c aused by a minute spar k, or
electric shock.
M ake k n ow n to all p e r s o nne l
concerned the risk of infrared
radiation. Failure to do so may
cause incorrect handling.
MANDATORY
ACTIONS
Caution
Use Control Unit that is suitable
for the Light Unit ratings. Using an
incorrect Control Unit can cause
PROHIBITED
Light Unit failure.
Use a standard Extension Cable
that is manufac tured by CC S.
However, if the cable is too long,
PROHIBITED
the light intensity will decrease due
to the DC resistance of the cable.
PROHIBITED
Places free from any water, oil, liquid,
chemical, or steam.
Places free from corrosive or combustible gas.
Places away from water faucets, boilers,
humidifiers, air conditioners, heaters, or stoves.
2
Confirming Product Information
The following tag is attached to the cable on the LED Light. The
back of the tag there is a name label that gives the model number,
power consumption, and serial number. Be sure to check the
contents before using the product and handle the label with care.
If the label is missing or damaged and the contents cannot be
checked, please contact CCS Inc.
Tag Example
Front
M O D E L
T H 2 - n n n x n n n I R n n n
I N P U T
S / N
M a n u f a c t u r e r :
C C S I n c .
Back
3 7 4 O k a k u e n c h o , K a m i g y o - k u ,
K y o t o 6 0 2 - 8 0 1 1 , J a p a n
E U I m p o r t e r :
C C S E u r o p e N . V .
B e r g e n s e s t e e n w e g 4 2 1 B ,
1 6 0 0 S i n t - P i e t e r s - L e e u w , B e l g i u m
M A D E I N J A P A N
3
Installation
Bottom Installation
Required Parts
M3 screws
Tap depth: 6 mm
MANDATORY
ACTIONS
Side Installation
MANDATORY
Required Parts
ACTIONS
M3 screws
Tap depth: 6 mm
MANDATORY
Recommended tightening torque: 0.6 N m
ACTIONS
4
Operating Instructions
MANDATORY
ACTIONS
Connect the light cable of the Light Unit to the Control Unit
1
output connector.
• Use a Control Unit that is
suitable for the Light Unit
ratings and is equipped
w i t h t h e c o r r e s p o n d i n g
MANDATORY
power output connectors.
ACTIONS
• Make sure that the Control
MANDATORY
ACTIONS
Unit is turned OFF before
connecting.
• Insert the plug all the way
MANDATORY
into the connector.
ACTIONS
Caution
D o n o t ex p o s e h u m a n eye s t o
infrared radiation. Also, make known
to all personnel concerned the risk
of infrared radiation.
Turn ON the Control Unit
2
and turn ON the Light Unit.
3
Adjust light range, light angle, and radiant quantity to optimize
images. Adjust the radiant quantity at the Control Unit.
The LEDs that appear to be not lit radiate infrared light. Do not look
Caution
at the radiated light directly with your naked eyes. To check for LED
radiation, use an infrared-enabled camera to look at the LEDs indirectly.
- 1 -
2 4 V = n . n W
0 1 2 3 4 5 6 7 8 9
Attach M3 screws to the tapped holes
on the bottom of the Light Unit to fix it.
Fix the Light Unit with M3 screw.
Inspection object
Infrared-enabled
camera
Read the instruction guide of the Control Unit
before use.
Tapped hole
M3 screws
M3 screws
TH2 series
Need help?
Do you have a question about the TH2 Series and is the answer not in the manual?
Questions and answers