Solutions to Possible System Errors
What Is Happening?
System will not turn on.
Touchpad turns on, but
turns off when a jack
button is pushed.
Touchpad turns on,
coach will not auto level.
Jacks will not extend
to ground, pump
is running.
Any one or two jacks
will not retract.
Jack bleeds down after
being extended.
No power to touchpad.
Rev: 10.23.23
Why?
Coach ignition not in
RUN position.
Parking brake not set.
Controls have been on for
more than four minutes
and have timed out.
Low voltage on battery.
Faulty pressure switch or
low pressure in system.
Little or no fluid
in reservoir.
Jack valve is inoperative.
Electronic signal is lost
between controller and
jack valves.
Hose damaged
or disconnected.
Return valve inoperative.
Electronic signal is
lost between controller
and solenoid.
Valve manual
override open.
Tripped circuit breaker.
Ignition not on.
What Should Be Done?
Turn ignition to RUN position.
Set parking brake.
Tap screen or turn ignition off and then back on.
Start coach to begin charging battery.
Plug vehicle in to charge house battery.
Check parking brake is engaged.
Re-calibrate level position.
Fill reservoir with recommended ATF.
Clean, repair or replace.
Trace wires for voltage drop or loss of signal. Repair or
replace necessary wires or replace controller.
Replace with new hose or reconnect hose.
Replace inoperative return valve.
Test for voltage drop between controller and jack valve.
Repair bad wiring or replace defective controller
or valve.
Close override.
Reset breaker.
Turn on.
Page 27
CCD-0005481