Menù 7 : Zone Module - Ariston ALTEAS ONE Training Manual

Wall hang boilers, condensation compact
Table of Contents

Advertisement

Training manual ALTEAS & GENUS ONE
9.3.6
Menù 7 : Zone module
7
1
MANUAL MODE
7
1
0
Manual mode activation
7
1
1
(set parameter 710 =1)
7
1
2
( set parameter 710 =1)
7
1
3
( set parameter 710 =1)
Zone 2 mix valve control
7
1
4
( set parameter 710 =1)
Zone 3 mix valve control
7
1
5
( set parameter 710 =1)
7
2
GENERAL ZONE MODULE
7
2
0
ΔT between zone delivery and
7
2
1
7
2
2
Auxiliary output setting
7
2
3
External temperature correction
7
8
ERROR HISTORY
7
8
0
7
8
1
RESET MENU'
7
9
7
9
0
Reset menu 7 factory setting
Page. 82 of 88
Function
Zone 1 pump control
Zone 2 pump control
Zone 3 pump control
Hydraulic scheme
boiler delivery (°C)
Last 10 errors
Reset error list
Range
0: Off
1: On
0: Off
1: On (timed 10 min)
0: Off
1: On (timed 10 min)
0: Off
1: On (timed 10 min)
0: Off
1: Open (timed o 10 min)
2: Close (timed 10 min)
0: Off
1: Open (timed 10 min)
2: Close (timed 10 min)
0: not defined
1: MCD
2: MGM II
3: MGM III
4: MGZ I
5: MGZ II
6: MGZ III
0 ÷ 40
(0= ΔT varible according the number of
zones that require heat; HT = +7°C
each zone; LT = +5°C each zone)
0: Heat request (to do a heat request to
a generic boiler)
1: External pump management
2: Alarm (the contact close if there is an
error regarding the zone module)
-3 ÷ 3
/
YES: push button "OK"
NO: push button "ESC"
YES: push button "OK"
NO: push button "ESC"
Default
setting
0
0
0
0
0
0
0
0
0
0
/
/
/
Version 2V2.