Errors; Remote Control (Rc) Errors Management - End User - Ariston ALTEAS ONE Training Manual

Wall hang boilers, condensation compact
Table of Contents

Advertisement

Training manual ALTEAS & GENUS ONE
8.3

ERRORS

The errors of boiler (and all components of the system connected through the Bus connection) are acquired
from the Gateway and can be visualized through Ariston Net, from the After sales service and from the end
user in different mode.
Remote control (RC) errors management – End user
8.3.1
The end user can only view the errors blockers for the boiler.
Is not possible to reset any error from remote (by App or by Web App).
While the error is active, the App is usable but is not allow any operation till the error will be solved.
On the Web App, when appears the error, contemporaneously appears also one notification.
Errors table viewable by the end user:
1 01
Overheat
Pressure Sens Error
1 02
Flow Check Failed
1 03
1 04
Flow Check Failed
Flow Check Failed
1 05
1 06
Flow Check Failed
1 07
Flow Check Failed
1 08
Filling Needed
1 11
Filling Needed
1 10
Send Probe Damaged
1 12
Return Probe Damaged
1 16
Floor Stat Open Circuit
1 18
Primary Probes Test Fail
2 01
DHW Probe Damaged
2 03
Tank Probe Damaged
DHW In Probe Open Circuit
2 05
2 51
DHW out sensor damaged
2 52
DHW in sensor damaged
3 01
Display EEPR err
PCB Fault
3 06
3 08
Config type mismatch
Gas Relais check Failed
3 09
4 11
Room Sensor not available Z1
4 12
Room Sensor not available Z2
4 13
Room Sensor not available Z3
Room Sensor not available Z4
4 14
4 15
Room Sensor not available Z5
Room Sensor not available Z6
4 16
4 30
MF Function not defined
MF Temp sensor 1 damaged
4 31
Page. 70 of 88
4 32
MF Temp sensor 2 damaged
MF Temp sensor 3 damaged
4 33
No flame detected
5 01
5 02
Flame Sensed with Gas Valve Closed
Flame lift
5 04
6 01
Fumes Overflow
6 02
Fumes Overflow
6 04
Low fan speed
6 05
Flue Sensor Open Circuit
6 07
APS on FAN off
6 08
APS off FAN on
6 10
Exchanger Probe Open Circuit
6 12
Fan Error
6 P1
APS late closing
6 P2
APS close-open
Low fan speed
6 P4
7 02
Zone2 Send Probe Damaged
7 03
Zone3 Send Probe Damaged
7 05
Zone5 Send Probe Damaged
Zone6 Send Probe Damaged
7 06
7 22
Zone2 Overheat
Zone3 Overheat
7 23
7 25
Zone5 Overheat
7 26
Zone6 Overheat
Version 2V2.