Co2 Adjustment - Intermediate Power - Ariston ALTEAS ONE Training Manual

Wall hang boilers, condensation compact
Table of Contents

Advertisement

Training manual ALTEAS & GENUS ONE
CO2 adjustment – Intermediate power
6.7.1
Switch on the boiler at the maximum power (using
1
"FLUE CLEANER" function  DHW max power)
Wait till the value of the CO2 on the exhaust
2
analyser is stable.
Compare the CO2 value with the values in the table
3
below.
If the CO2 value is not ok press "OK" button and the
4
display shows the adjustment bar.
Using the buttons "<" and ">" to adjust the CO2
value (it is possible modify the CO2 of a value
±0,5%).
5
Note: To see the CO2 variation it needs to finish
this procedure and perform 5 ignitions of the
boiler.
To save the new setting push the button "Ok"
6
Type of gas
12KW
G20 20 mb
8,6% ± 0,7
G30 29 mb
G31 37 mb
10,0% ± 0,7
G231
N.B.: Values with casing closed.
CO2
18 KW
24 KW
8,6% ± 0,7
8,6% ± 0,7
10,0% ± 0,7
10,0% ± 0,7
30 KW
35KW
8,6% ± 0,7
8,6% ± 0,7
10,0% ± 0,7
10,0% ± 0,7
Page. 51 of 88