"AIR PURGE" Function

4.5
This function can be activated by the installer by the parameter
5 sec (continues till to the finish (about 6') or pressing of the mode button
Lo scopo di tale funzione è quello di aiutare ad espellere l'aria dal circuito primario dopo un riempimento.
It's aim is to help to purge the residual air inside the primary circuit after a filling cycle. At the activation the
following cycle is begun:
3 way valve in heating
Pump on 60 sec.
Pump off 30 sec.
Pump on 60 sec.
This cycle can be repeated several times, till the boiler and the heating system are completely purged from
air.
3 way valve in sanitary
Pump on 60 sec.
Using the manual air purge on the heat exchanger it is possible drain
the ait from it.
2 71
or pressing of the mode button
).
3 way valve in heating
Pump on 60 sec.
Pump off 30 sec.
Pump on 60 sec.