Igniter / Elecrode Probes; Spark Generator - Ariston ALTEAS ONE Training Manual

Wall hang boilers, condensation compact
Table of Contents

Advertisement

Training manual ALTEAS & GENUS ONE
6.9

IGNITER / ELECRODE PROBES

There is only one electrode that produces ignition and detects the presence of the flame in the burner if the
ionization current is more than 1 µA. If the signal disappears, three attempts are made to try to ignite the
burner.
Distance between the ignition electrodes: 3±0,5 mm.
Distance between the burner and the electrodes: 5±1 mm.
6.1

SPARK GENERATOR

Integrated in main PCB.
Ionisation probe
PCB
110 v ~
I ionisation
Flame