Information about this document
1.1
Contents and purpose
1
1
This document supplements the SVA/SVI locks'
1
assembly instructions and contains technical
1
information for the mounting and commissioning of
1
an SVA 2xxx or SVA 2xxxF lock.
2
1.2
Target group
2
2
The locks may only be mounted by technical
2
specialists who have been trained for this purpose by
2
dormakaba.
2
1.3
Other applicable documents
2
2
• SVA/SVI locks assembly instructions
3
• Manual for the connecting cable SVP-A 1100/2100
3
• Technical documents for the selected control unit
3
• Commissioning instructions for the SVI lock
3
• Assembly instructions for the fittings used, e.g. door
handles, panic bar or knob.
3
1.4
Abbreviations
4
4
4
Active, self-locking
4
SVA
(anti-)panic lock for the active
4
door leaf in 2-leaf door units
4
4
Inactive, self-locking (anti-)panic
5
SVI
lock for the passive door leaf in
5
2-leaf door units
5
5
All versions of a lock; the exact
6
2xxx/2xxxF
lock type is marked with 3 digits
6
instead of xxx.
7
G
Active door leaf
7
7
S
Passive door leaf
7
DCW is short for "DORMA
8
Connect & Work".
9
A dormakaba-owned fieldbus
9
DCW bus
system for the connection of up
10
to 4 identical components to a
10
DCW central unit.
10
10
Serial fieldbus system according
10
to ISO 11898-3, for connecting
CAN bus
11
several components to one cable
harness
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SVA 2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba SVA 2 Series

  • Page 1: Table Of Contents

    Passive door leaf Requirements DCW is short for "DORMA 6.2 Parameterizing Connect & Work". 6.2.1 Set for DCW bus A dormakaba-owned fieldbus 6.2.2 Set for CAN bus DCW bus system for the connection of up 6.2.3 Set for Stand Alone mode to 4 identical components to a...
  • Page 2: Symbols Used

    In case of emergency, the door can on 2-leaf door units. be opened in the escape direction at any time. The • Use only the components approved by dormakaba SVA lock canquery the status of the trip latch, bolt, for mounting: door handle/panic bar and the locking cylinder.
  • Page 3: Parts Included

    SVA 2xxx/SVA 2xxxF Commissioning instructions Automatically opening installation example Bolt throw: 20 mm 20 mm Temperature range: -25°C to +70°C Relative humidity: up to 95% at 55°C no condensation Variants (F) = Version with integrated Power Reserve module. These versions cannot be switched "permanently open".
  • Page 4: Led Display At System Start

    SVA 2xxx/SVA 2xxxF Commissioning instructions LED display Operation modes The SVA lock shows colored light signals in the area The lock can be controlled in 3 operation modes. The around the bolt. The LED is covered by the forend operation mode determines whether and how the and is not directly visible.
  • Page 5: Classification

    SVA 2xxx/SVA 2xxxF Commissioning instructions Classification Pin assignment 3.8.1 Tubular frame locks NOTE dormakaba Deutschland GmbH For earthed door frames, the bridge on the DORMA Platz 1 - 58256 Ennepetal SVP-A x100 connection cable’s plug must be disconnected. 0432-CPR-00026-97 SVA 2xxx RR 3 S 6 E* 0 M 7 1 1**/3...
  • Page 6: Block Diagram Sva 2Xxx(F) Can

    SVA 2xxx/SVA 2xxxF Commissioning instructions Block diagram SVA 2xxx(F) CAN SVP/SVZ/ SVA 2xxx (F) Black GND (3) function Brown not in use Pink/gray not in use not in use White +24 VDC (1) (stabilized) Yellow CAN (L) Green CAN (H) Gray RS485 N (only in combination with SVI 2xxxF) Pink RS485 P (only in combination with SVI 2xxxF) Red/blue...
  • Page 7: Block Diagram Sva 2Xxx(F) Stand Alone

    NOTE Read the entire procedure. Changed parameters must be saved within 5 min, otherwise parameterization is aborted, (see Chapter 6.2.6). https://techdoc.dormakaba.com/cds/go/SVA-SVI SVI commissioning manuals NOTE If parameterization is not possible, check the fit of the cylinder cam. The cylinder must touch the cylinder contact.
  • Page 8: Parameterizing

    SVA 2xxx/SVA 2xxxF Commissioning instructions Parameterizing Symbol Operating method The parameters are set from the inside of the door in To jump from setting to setting its installed state. The switches in the door lock are within a selection: operated with a door handle or key. Briefly press down the door handle until it stops.
  • Page 9: Set For Dcw Bus

    SVA 2xxx/SVA 2xxxF Commissioning instructions 6.2.1 Set for DCW bus 6.2.2 Set for CAN bus Address assignment is only required in conjunction with a SafeRoute system with multi-door application. NOTE In the EntriWorX EcoSystem, the address NOTE assignment takes place automatically in Address assignment for combination of the CAN bus.
  • Page 10: Set For Stand Alone Mode

    Check correct wiring. CAN bus connection interrupted Check correct wiring. Disconnect and reactivate the power supply for the door. If the General error error persists, call dormakaba Service. Bus cable disrupted in the operation mode Power on again. CAN mode...
  • Page 11: Disassembly And Disposal

    SVA 2xxx/SVA 2xxxF Commissioning instructions Disassembly and disposal Disassembly is carried out in reverse order of the mounting instructions. The product must not be disposed of in domestic waste. Dispose of the product in an environmentally friendly manner at the arranged acceptance and collection points.