SVA/SVI Mounting instructions Contents Information about this document 3.4 Preparations for mounting Contents and purpose 3.5 Installation steps Target group 3.6 Establish electrical connection Other applicable documents (only in the case of electrical locks) Abbreviations 3.7 Parameterize lock Symbols used (SVA locks of series 2xxx and 2xxxF only) 1.5.1 Hazard categories...
Danger to life from crowding in front of a plug for the upper espagnolette bolt, a mounting aid jammed door. for the upper espagnolette bolt and the dormakaba If the door leaf is deformed by more than torque tool. 5 mm, the door may not always open reliably! •...
SVA/SVI Mounting instructions Requirements for mounting 3.3.1 Tubular frame door variants • The maximum permissible door leaf dimensions are: Max. weight 300 kg Height max. 3500 mm Width max. 1800 mm • The door leaves are not deformed. Overview of parts door lock on the active door leaf door lock on the passive door leaf Rod striking plate Switch lock...
SVA/SVI Mounting instructions Maintenance Preparations for mounting • Prepare the door leaves, door frame and Perform the following maintenance steps espagnolette bolts according to the dimension at least once a month to ensure safe use of drawings in the image section. Align all recesses the SVA/SVI lock: with the selected fittings on site.
SVA/SVI Mounting instructions Image section Dimensions SVA 2xxxF SVA 2xxx SVA 4xxx SVA 5xxx SVA 6xxx SVA xx7x = 65 mm SVA xx8x = 80 mm SVA xx9x = 100 mm 2.5—5 DSVA Ø 22 Ø 7 Ø 7 Ø 8 Ø 7 Ø 7 PC Ø 17 RC Ø...
Page 7
SVA/SVI Mounting instructions 101/105 Ø 5.5 SVI 20xxF 19.5 SVI 40xx SVI 50xx 2–7 SVI xx7x = 65 mm SVI xx8x = 80 mm Ø 5.5 SVI xx9x = 100 mm 2.5–5 min. Ø 15 Ø 22 Ø 7 Ø 7 min.Ø 15 Ø...
Page 8
SVA/SVI Mounting instructions 101/105 Ø 5.5 SVI 20xxF 19.5 SVI 40xx SVI 50xx 2–7 SVI xx7x = 65 mm SVI xx8x = 80 mm SVI xx9x = 100 mm Ø 5.5 X=DSVI-35 Y=DSVI-27 DSVI 2.5–5 min.Ø 15 Ø 22 Ø 7 Ø 7 max.
Page 9
SVA/SVI Mounting instructions SVA 2xxx SVA 2xxxF SVA 4xxx SVA 5xxx SVA 6xxx SVA xx19 = 35 mm DSVA-3 SVA xx29 = 40 mm SVA xx39 = 45 mm DSVA 3.5–6*2 <19 Ø 22 PC Ø 17 RC Ø 22 10.5 *1) ST 3.9x19 A2-70 (EN ISO 7050) *2) for SVA RR with U-forend 060644-45532 –...
Page 10
SVA/SVI Mounting instructions 101/105 SVI 4xxx SVI 5xxx Ø 5.5 19.5 2–7 SVI xx19 = 35 mm DSVI-3 SVI xx29 = 40 mm DSVI SVI xx39 = 45 mm 3.5–6*4 Ø 25 Ø 10 DSVI-3 Ø 6 Ø 15 20 20 *1) ST 3.9x19 A2-70 2–7 (EN ISO 7050) *2) with max.
Page 11
SVA/SVI Mounting instructions 101/105 SVI 21xxF Ø 5.5 19.5 2–7 Ø 5.5 DSVI-3 SVI xx19 = 35 mm SVI xx29 = 40 mm DSVI SVI xx39 = 45 mm 3.5–6*4 Ø 25 Ø 10 DSVI-3 Ø 6 Ø 15 20 20 *1) ST 3.9x19 A2-70 2–7 (EN ISO 7050)
Page 16
SVA/SVI Mounting instructions 1 mm 060644-45532 – 05/2023...
Page 17
SVA/SVI Mounting instructions 1.3 Nm 1.3 Nm ATTENTION When tightening the screw, the lock must be unlocked on tubular frame doors and locked on solid doors. Do not use the door handle for solid doors. 060644-45532 – 05/2023...
Need help?
Do you have a question about the SVA 2000 and is the answer not in the manual?
Questions and answers