Table 4 Non-Port Side Led Patterns During Normal Operation - Brocade Communications Systems VDX 6730 Hardware Reference Manual

Hide thumbs Also See for VDX 6730:
Table of Contents

Advertisement

4
LED activity interpretation
Table 4
TABLE 4
LED name
Power supply and
fan assembly
status (one LED
[green] per power
supply and fan
assembly)
(Brocade VDX
6730-32)
Power supply
status(one LED
[green] per power
supply) (Brocade
VDX 6730-76)
30
describes the LEDs on the non-port side of the switches.
Non-port side LED patterns during normal operation
LED color
Off (no light)
Steady green
Blinking green
Off (no light)
Steady green
Blinking green
Status of hardware
Assembly is not receiving power
or is turned off.
Assembly is operating normally.
One of the following may have
occurred:
Mismatched airflow on
power supply and fan
assembly on the Brocade
VDX 6730-32.
One or more of the fans in
the fan assembly has failed
or the power supply has
failed.
The power cord has been
unplugged.
Power supply is not receiving
power or is off.
Power supply is operating
normally.
Also, airflow mismatch or fault
may have been detected.
Power supply is faulty.
Brocade VDX 6730 Hardware Reference Manual
Recommended action
Verify the assembly is on and seated
and the power cord is connected to a
functioning power source.
No action required.
Take one of the following actions:
Replace power supply and fan
assembly with a power supply and
fan assembly that has correct
airflow direction. Replace if
necessary.
Replace the power supply and fan
assembly.
Check the power plug.
Verify the power supply is on and
seated and the power cord is
connected to a functioning power
source.
No action required.
Use the show environment command
to check the state of the power supply.
Try the following:
Check the power cable
connection.
Verify that the power supply is
powered on.
Replace the power supply.
53-1002389-06

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vdx 6730-32Vdx 6730-76

Table of Contents