Brocade VDX 6720
QuickStart Guide
Supporting the VDX 6720-24 and VDX 6720-60
53-1002085-03
*53-1002085-03*
®

Advertisement

Table of Contents
loading

Summary of Contents for Brocade Communications Systems VDX 6720-24

  • Page 1 53-1002085-03 ® 5 August 2013 Brocade VDX 6720 QuickStart Guide Supporting the VDX 6720-24 and VDX 6720-60 53-1002085-03 *53-1002085-03*...
  • Page 2 Copyright © 2010-2013 Brocade Communications Systems, Inc. All Rights Reserved. ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries.
  • Page 3: Items Included With The Brocade Vdx 6720

    Overview This Quick Start guide is intended as an overview to help experienced installers unpack, install, and configure the Brocade VDX 6720 quickly. For more detailed installation and configuration instructions, see the Brocade Network OS Administrator’s Guide and the Brocade Network OS Command Reference Manual. NOTE Throughout this document, the Brocade VDX 6720 is referred to as the switch.
  • Page 4: Environmental Considerations

    TABLE 1 Power Supply Specifications Specification Value Maximum output 250 watts, 4 amps, 12 VDC - VDX 6720-24 500 watts, 7 amps, 12 VDC - VDX 6720-60 Maximum AC power consumption 146.2 W - VDX 6720-24 360 W - VDX 6720-60 System DC power consumption (excluding power supply Idle: 182.4 W...
  • Page 5: Recommendations For Cable Management

    Recommendations for cable management The minimum radius to which a 50 micron cable can be bent under full tensile load is 5.1 cm (2 in.). For a cable under no tensile load, that minimum is 3.0 cm (1.2 in.). Cables can be organized and managed in a variety of ways; for example, use cable channels on the sides of the cabinet or patch panels to reduce the potential for tangling the cables.
  • Page 6: Providing Power To The Switch

    2. Power on the Brocade VDX 6720-24 by turning both on/off switches to "I." The Brocade VDX 6720-60 powers up automatically when plugged in. The power supply LEDs display amber until POST is complete, and then change to green.
  • Page 7: Assigning Permanent Passwords

    Complete the following steps to create a serial connection to the switch. 1. Connect the serial cable to the serial port on the switch and to an RS-232 serial port on the workstation or terminal device. If the serial port on the workstation or terminal device is RJ45 instead of RS-232, remove the adapter on the end of the serial cable and insert the exposed RJ45 connector into the RJ45 serial port on the workstation.
  • Page 8: Setting The Switch Ip Address

    The root account is reserved for development and manufacturing. The user account is read-only and used primarily for system monitoring. TABLE 3 Default administrative account names and passwords Account type Login name Password Administrative admin password User account (read-only) user password Changing the default account passwords When you change the default account password after you log in for the first time, only the default password rule is in...
  • Page 9: Enabling And Disabling Brocade Vcs Mode

    Enabling and disabling Brocade VCS mode Enable or disable a single switch for VCS™ mode as soon as passwords have been assigned and an IP address has been set. Enabling VCS mode is disruptive since a reboot is required once the mode has been enabled. Enabling or disabling VCS mode also causes the default configuration file for that mode to be applied.
  • Page 10: Configuring Switch Ports

    This is important to capture any changes that have been made to the running configuration so that they will persist the next time the switch reboots in the same mode. Configuring switch ports By default, the interfaces are not configured as switch ports. In order to put an interface in Layer 2 mode, use the following command in Interface Configuration mode.
  • Page 11 FIGURE 1 Installing an SFP+ transceiver in the upper row of port slots 4. If this is not a direct-connect unit, remove the protective caps from the cable end and position the cable so that it is correctly oriented to the transceiver. 5.
  • Page 12: Connecting To Ethernet Or Fast Ethernet Hubs

    Connecting to Ethernet or fast Ethernet hubs For copper connections to Ethernet hubs, a 1000Base-T switch, or another Brocade device, a crossover cable is required. If the hub is equipped with an uplink port, it requires a straight-through cable instead of a crossover cable. NOTE The 802.3ab standard (automatic MDI or MDIX detection) calls for automatic negotiation of the connection between two 1000Base-T ports.