Brocade Communications Systems VDX 6710 Hardware Reference Manual
Brocade Communications Systems VDX 6710 Hardware Reference Manual

Brocade Communications Systems VDX 6710 Hardware Reference Manual

Table of Contents

Advertisement

Quick Links

DRAFT: BROCADE CONFIDENTIAL
53-1002xxx-01
®
xx September 2011
Brocade VDX 6710
Hardware Reference Manual

Advertisement

Table of Contents
loading

Summary of Contents for Brocade Communications Systems VDX 6710

  • Page 1 DRAFT: BROCADE CONFIDENTIAL 53-1002xxx-01 ® xx September 2011 Brocade VDX 6710 Hardware Reference Manual...
  • Page 2 Wingspan are registered trademarks, and Brocade Assurance, Brocade NET Health, Brocade One, Extraordinary Networks, MyBrocade, and VCS are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
  • Page 3: Table Of Contents

    In this chapter ..........1 Brocade VDX 6710 overview ....... . 1 Platform components and capabilities.
  • Page 4 LED activity interpretation ....... . . 23 Brocade VDX 6710 LEDs ....... 23 LED locations .
  • Page 5 Before beginning the installation ......33 Replacing a combined FRU in a Brocade VDX 6710... . . 34 Time and items required .
  • Page 6 DRAFT: BROCADE CONFIDENTIAL Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 7: About This Document

    Appendix A, “Brocade VDX 6710 Specifications” provides tables of physical, environmental, and general specifications. Supported hardware and software This document is specific to the Brocade VDX 6710-24 and the Brocade VDX 6710-60 under Network OS v2.1.0. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 8: Document Conventions

    Boolean. Elements are exclusive. Example: show mode egress | ingress Notes, cautions, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards. viii Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 9: Key Terms

    Netscape Communications Corporation Netscape Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover Velcro Industries B.V. Velcro Additional information This section lists additional Brocade and industry-specific documentation that you might find helpful. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 10: Brocade Resources

    Detailed description of the problem, including the switch or fabric behavior immediately following the problem, and specific questions • Description of any troubleshooting steps already performed and the results • Serial console and Telnet session logs • syslog message logs 2. Switch Serial Number Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 11: Document Feedback

    Forward your feedback to: documentation@brocade.com Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 12 DRAFT: BROCADE CONFIDENTIAL Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 13: Chapter 1 Brocade Vdx 6710 Introduction

    • Views of the Brocade VDX 6710 switch ......4 Brocade VDX 6710 overview The Brocade VDX 6710 is a top-of-rack switch designed to accommodate traditional 1 Gigibit Ethernet (GbE) server connections to the Brocade 10 GbE VCS™...
  • Page 14: Software Features

    • Triple, hot-swappable cooling fans in an n+1 configuration Software features The Brocade VDX 6710 switches support the following features. For more details on these features, refer to the Brocade Network OS Administrator’s Guide. Brocade VDX 6710 Hardware Reference Manual...
  • Page 15 Out-of-band management (standalone mode) • sFlow • TRILL Operations, Administration, and Management (OAM) • Distributed configuration management (DCM) Licensing • VCS licensing: available multi-node license up to 10 nodes (enables Ethernet Fabric functionality Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 16: Views Of The Brocade Vdx 6710 Switch

    Views of the Brocade VDX 6710 switch Views of the Brocade VDX 6710 switch The port side of the Brocade VDX 6710 switch includes the system LEDs, management ports and LEDs, USB port, and Gigabit Ethernet (GbE) ports and the corresponding port status LEDs.
  • Page 17 DRAFT: BROCADE CONFIDENTIAL Views of the Brocade VDX 6710 switch Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 18 DRAFT: BROCADE CONFIDENTIAL Views of the Brocade VDX 6710 switch Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 19: In This Chapter

    Standalone installation for a Brocade VDX 6710 ..... . 9 • Rack installation for a Brocade VDX 6710......10 •...
  • Page 20: Electrical Considerations

    • Because the Brocade VDX 6710 switches can be ordered with fans that either move air front to back or back to front, be sure to orient your switch with the airflow pattern of any other devices in the rack.
  • Page 21: Items Required For Installation

    Keep LEDs visible by routing port cables and other cables away from the LEDs. Items required for installation The following items are required for installing, configuring, and connecting the Brocade VDX 6710 switches for use in a network and fabric: •...
  • Page 22: Rack Installation For A Brocade Vdx 6710

    Installation Procedure. Providing power to the switch Perform the following steps to provide power to the Brocade VDX 6710. 1. Connect the power cords to both power supplies, and then to power sources on separate circuits to protect against failure. Ensure that the power cords have a minimum service loop of 15.2 cm (6 in.) available and are routed to avoid stress.
  • Page 23 DRAFT: BROCADE CONFIDENTIAL Verifying operation Table 2 on page 25 and Table 3 on page 27 for more details on the LED patterns. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 24 DRAFT: BROCADE CONFIDENTIAL Verifying operation Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 25: In This Chapter

    In this chapter • Configuration modes for the Brocade VDX 6710 ..... 13 • Creating a serial connection ........14 •...
  • Page 26: Creating A Serial Connection

    The rule specifies a minimum password length of eight characters. For advanced user and role management, including setting password rules, refer to the Security chapter of the Brocade Network OS Administrator’s Guide. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 27: Setting The Switch Ip Address

    Setting the switch IP address You can configure the Brocade VDX 6710 with a static IP address, or you can use a Dynamic Host Configuration Protocol (DHCP) server to set the IP address of the switch. DHCP is enabled by default.
  • Page 28: Setting Stateless Ipv6 Autoconfiguration

    IP address has been set. Enabling VCS mode is disruptive since a reboot is required once the mode has been enabled. Enabling or disabling VCS mode also causes the default configuration file for that mode to be applied. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 29: Enabling Vcs Mode

    Another parameters that can be changed if necessary is the VCS ID. This identifies the VCS fabric of which the switch can be a part. By default, the VCS of every VDX 6710 is 1. Change the VCS ID if you need to create a new, separate VCS fabric.
  • Page 30: Setting The Date And Time

    (RTC) circuit. Date and time are used for logging events. Switch operation does not depend on the date and time; a Brocade VDX 6710 with an incorrect date and time value functions properly. Because the date and time are used for logging, error detection, and troubleshooting, you should set them correctly.
  • Page 31: Synchronizing Local Time Using Ntp

    Example of setting the clock to March 17, 2010, 15 minutes past noon: switch:admin > clock set 2010-03-17T12:15:00 3. To show the clock and time zone settings, use the show clock command. switch:admin > show clock [switchid <switchid> | all] Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 32: Setting Time Zones

    For direct attachment from the Brocade device to a Gigabit NIC, switch, or router, fiber cabling with an LC connector is required. See “Installing an SFP+ transceiver” on page 26 for details about installing SFPs and cables. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 33: Testing Connectivity

    All ports must be in the same port group and must be configured at the same speed. There is a limit of eight ports per trunk group. No separate licensing is required. For more information about Brocade trunks, see the Brocade Network OS Administrator’s Guide. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 34 DRAFT: BROCADE CONFIDENTIAL Creating Brocade inter-switch link trunks Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 35: Brocade Vdx 6710 Operation

    • Brocade VDX 6710 maintenance ........29 •...
  • Page 36: Led Locations

    One bicolor (green and amber) port status LED for each port on the switch. These LEDs are arrayed above each pair of Ethernet ports on the VDX 6710 and below each pair on the VDX 6710. The left LED corresponds to the upper port of the pair and the right LED corresponds to the lower port.
  • Page 37: Led Patterns

    LOMM [Remote Lights Out] port) Ethernet Off (no light) There is no activity. No action required. Activity Blinking green There is activity (traffic). No action required. (Management and LOMM [Remote Lights Out] port) Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 38 Steady amber Port enabled, link down. No action required. Fast blinking amber Error. ??? What action is required. (1/2 second interval) Slow blinking amber Port disabled. ??? Enable the port. (2 second interval) Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 39: Post And Boot Specifications

    POST can be several minutes. POST can be omitted after subsequent reboots by using the fastboot command or entering the no diag post command to persistently disable POST. For more information about these commands, refer to the Network OS Command Reference Manual. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 40: Post

    If this is not successful, the switch did not successfully complete POST. Contact your switch supplier for repair. 3. Review the switch system log for errors. Any errors detected during POST are written to the system log, accessible through the show logging raslog command. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 41: Brocade Vdx 6710 Maintenance

    Brocade Network OS Administrator’s Guide. For information about error messages, refer to the Fabric OS Message Reference. Brocade VDX 6710 maintenance The Brocade VDX 6710 is designed for high availability and low failure; it does not require any regular physical maintenance. The SFPs and diagnostic tests are described in the following sections.
  • Page 42: Maybe Need Direct-Attach Copper Example

    Brocade Network OS Command Reference Guide for more details about diagnostic tests and commands. Diagnostic tests run at link speeds of 1 or 10 Gbps (GbE) depending on the speed of the link being tested and the type of port. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 43: Brocade Vdx 6710 Management - Mgmt Cluster

    Brocade VDX 6710 management - Mgmt Cluster??? You can use the management functions built into the Brocade VDX 6710 to monitor the fabric topology, port status, physical status, and other information to help you analyze switch performance and to accelerate system debugging.
  • Page 44 DRAFT: BROCADE CONFIDENTIAL Brocade VDX 6710 management - Mgmt Cluster??? Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 45: Chapter 5 Fru Removal And Replacement Procedures

    Before beginning the installation ........33 • Replacing a combined FRU in a Brocade VDX 6710 ....34 Before beginning the installation The field-replaceable units (FRUs) in the Brocade VDX 6710 switches can be removed and replaced without special tools.
  • Page 46 This is called back-to-front airflow or reverse airflow. This symbol should appear on FRUs with part numbers ending with -R.. The show environment fan command will indicate either “forward” or “reverse” airflow. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 47: Replacing A Combined Fru In A Brocade Vdx 6710

    Replacing a combined FRU in a Brocade VDX 6710 Figure 7 shows the two combined AC power supply and fan assemblies in the Brocade VDX 6710-. The Network OS identifies the FRUs from left to right as power supply and fan assembly #2 and power supply and fan assembly #1.
  • Page 48: Time And Items Required

    Replacing a combined power supply and fan assembly in the switch should take less than two minutes. You need the following items to replace a power supply and fan assembly in a Brocade VDX 6710: • A new power supply and fan assembly (must have the same part number and the same airflow label as the power supply and fan assembly being replaced) •...
  • Page 49 DRAFT: BROCADE CONFIDENTIAL Replacing a combined FRU in a Brocade VDX 6710 1. Unplug the power power cords from the combined power supply and fan assembly you are replacing. 1. Unscrew the captive screw on the power supply and fan assembly you are replacing using the Phillips screwdriver.
  • Page 50 P/N: xxxxxxx-xx Brocade VDX 6710 chassis Label with part number DC power supply and fan assembly Captive screw FIGURE 10 Orientation of the DC power supply and fan assembly in the Brocade VDX 6710 Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 51 DRAFT: BROCADE CONFIDENTIAL Replacing a combined FRU in a Brocade VDX 6710 4. Verify that the power supply and fan assembly status LED is steady green to indicate normal operation (see Table 5 for more LED information). You can also display the power supply and fan assembly status using the following commands from the CLI: •...
  • Page 52 DRAFT: BROCADE CONFIDENTIAL Replacing a combined FRU in a Brocade VDX 6710 Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 53: In This Appendix

    Environmental regulation compliance ......48 Weight and physical dimensions Table 6 lists the weight and dimensions of the Brocade VDX 6710 switches. TABLE 6 Physical specifications...
  • Page 54: Facility Requirements

    DRAFT: BROCADE CONFIDENTIAL Facility requirements Facility requirements Table 7 provides the facilities requirements that must be met for the Brocade VDX 6710 switches. TABLE 7 Facility requirements Type Requirements • Electrical Primary AC input 85-265 VAC nominal, 47-63 Hz; switch autosenses input voltage •...
  • Page 55: Environmental Requirements

    Maximum - 101.9 cmh (60 cfm) Nominal - 74.8 cmh (44 cfm) Heat dissipation 1044 BTU/hr General specifications Table 10 lists the general specifications for the Brocade VDX 6710 switch. TABLE 10 General specifications Specification Description System architecture Nonblocking shared-memory switch System processor Freescale MPC8548??? x 1.3 GHz...
  • Page 56: Data Transmission Ranges

    Up to 500 km at 1 Gbps is supported when using a long distance transport system such as DWDM. Memory specifications The Brocade VDX 6710 has three types of memory devices, boot:flash, compact flash, and main memory. The size of each is listed in...
  • Page 57: Fcc Warning (Us Only)

    This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance might arise. When such trouble occurs, the user might be required to take corrective actions. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 58: Power Cords (Japan Denan)

    The standards compliance label on the Brocade VDX 6710 contains the CE mark which indicates that this system conforms to the provisions of the following European Council directives, laws, and standards: •...
  • Page 59: Canadian Requirements

    Standards, 21 CFR Subchapter I and the international laser safety standard IEC 825-2. ATTENTION Use only optical transceivers that are qualified by Brocade Communications Systems, Inc. and comply with the FDA Class 1 radiation performance requirements defined in 21 CFR Subchapter I, and with IEC 825-2.
  • Page 60: Dc-Dc Power Source Cautions

    2 mm² doit être fixé à un raccord à sertir agréé (directement présent sur le châssis du VDX 6710/6720/6730) à l'aide de la pince à sertir appropriée. Le raccord à sertir doit pouvoir être raccordé aux deux vis de mise à...
  • Page 61: Regulatory Certifications

    Regulatory certifications CAUTION For the DC input circuit to the system of a VDX 6710/6720/6730, make sure there is a UL-Listed 15 amp circuit breaker, minimum 48Vdc, double pole, on the input lugs to the power supply. The input wiring for connection to the product should be Listed copper wire, 14 AWG, marked VW-1, and rated minimum 90°C...
  • Page 62: Environmental Regulation Compliance

    The EPUP assumes that the product will be used under normal conditions in accordance with the operating manual of the product. (EPUP) EPUP Brocade Brocade ocade EPUP Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 63: Ts/Hs Dual Language Sheet

    X indicates that the concentration of such hazardous/toxic substance in all the units of homogeneous material of such component is higher than the SJ/T11363-2006 Requirements for Concentration Limits. O indicates that no such substances are used or that the concentration is within the aforementioned limits. Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 64 DRAFT: BROCADE CONFIDENTIAL Environmental regulation compliance Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 65 IP address terminal emulator configuration modes configure terminal command copy running-config startup-config command data transmission ranges diagnostic tests distributed intelligence Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 66 NTP server access interpreting ntp server command LED activity POST results inter-switch links ip address command ip address dhcp physical dimensions ip gateway-address platform components ipv6 address autoconfig command port side view ISL trunking POST Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 67 VDX 6720-24 SNMP non-port side LED indications software features virtual cluster switching specifications see VCS general memory power supplies static IP address IPv4 weight IPv6 switch capabilities management port side view switch features Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...
  • Page 68 DRAFT: BROCADE CONFIDENTIAL Brocade VDX 6710 Hardware Reference Manual 53-1002xxx-01...

Table of Contents