Fig. 11: Cam era front (sectional view )
The data given in the table include the following tolerances as a safety clearance:
·
Immersion depth: 0.2 mm
·
Diameter: 0.2 mm
Type
Thread depth
(min.)
C-mount
5 mm

5.4 Position accuracy of the sensor

The following illustrations show the tolerance margins of the sensor position relative to the outer camera front.
A maximum error in all directions (rotation, translation) cannot occur at the same time.
Fig. 12: Position accuracy of the sensor (1)
It cannot be guaranteed that the sensor cover glass or filter glass are absolutely parallel to each other.
C-mount/TFL-mount lenses can also be subject to inaccuracies of the flange back distance.
The tolerance usually is ±0.05 mm. In some cases, however, the inaccuracies of camera and
lens might add up, resulting in a total error > 0.05 mm.
Position accuracy, in each direction
2023-10-25
For diameter at lens
end [mm]
Ø A
24.0
IDS NXT malibu: Technical Manual
Resulting maximum
immersion depth [mm]
11.0
Fig. 13: Position accuracy of the
sensor (2)
±0.3 mm
Minimum required back
focal length [mm]
6.5