4.4.4 Digital output wiring

Recommended supply voltage
Collector-emitter saturation voltage
Collector-emitter breakdown voltage
Collector current continuous
The digital output is galvanically isolated using an optocoupler to protect the camera and the PC against
surges. Only DC voltages may be applied to the digital output.
The output of the optocoupler can be used as an open collector or open emitter output. This means that the
output signal can be connected to ground or to the supply voltage. The output signal is active if the collector-
emitter switch is closed.
You need an additional, external supply voltage for the output wiring, which is independent of the supply voltage
of the camera.
Open collector wiring
Pin 2 is the reference level (GND) for the output.
2023-10-25
Icon
V
CC
V
CE(SAT)
V
(BR)CE
I
C
Fig. 4: Open collector w iring
IDS NXT malibu: Technical Manual
Minimum
Typical
-
-
0.03
-
100
-
-
-
Maximum
Unit
30
V
0.15
V
-
V
150
mA
16