PROBLEM
CAUSE
Faulty fume tempe-
The exchanger fan
rature probe
continues to turn
even though the
stove has just cooled
Faulty mother board Replace the mother board.
Faulty or out of order
door gaskets
Ash remains along
the stove
Not sealed fume
pipes
The stove is at its
Ambient temperatu-
highest power but
re reached.
does not heat up.
Stove running and
display showing
Reached fume outlet
"Smoke Overtepe-
limit temperature
rature"
The stove's smoke
Low smoke tempe-
duct produces
rature
condensation
Stove running and
Routine maintenan-
display showing
ce alert (it does not
"SERVICE"
block the system)
32
SOLUTION
Replace the fume probe.
Replace the gaskets.
Contact an expert stove-repairer who will immediately provide for
sealing the junctions with high-temperature silicone and/or for
replacing pipes with those in compliance to current regulations. A
not sealed fume channelisation can be noxious to health.
The stove is at its minimum value. Increase the desired ambient
temperature.
The stove runs at minimum. NO PROBLEM!
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance.
Contact the service centre.