PROBLEM
CAUSE
Empty hopper
Open fire door or
open pellet door
Clogged stove
Pellets do not reach
the combustion
Auger blocked by a
chamber
foreign object (for
example nails)
The auger geared
motor is out of order Replace the geared motor.
Check if on the
display there is an
"ACTIVE ALARM"
Empty hopper
Auger blocked by a
foreign object (for
example nails)
The fire extinguish
Bad quality pellets
and the stove stops
Pellet drop value too
low "phase 1"
Check if on the
display there is an
"ACTIVE ALARM"
Not sufficient com-
bustion air
Flames are weak and
Obstructed exhaust
orange coloured,
pellets do not burn
properly and the
Obstructed stove
glass blackens
The fume fan is out
of order
KOBE - FENICE - SPARK - INDACO - PRINCE - GO - ECLIPSE
SOLUTION
Full the hopper.
Close fire door and pellet door and check that there are no pellet
grains at the gasket level.
Fume chamber cleaning
Clean the auger.
Have the stove checked.
Full the hopper.
Clean the auger.
Try other types of pellets.
Adjust the pellet loading.
Have the stove checked.
Check as following: probable obstructions of the combustible air
inlet from the back or from the bottom of the stove; burning pot
obstructed holes with too ash remains. Have the fan blades and
auger cleaned. (see SMOKE RPM VARIATION User Manual)
The exhaust chimney is partially or totally obsturcted. Contact an
expert stove-repairer who checks the stove from the exhaust up to
the chimney pot. Provide immediately for stove cleaning.
Provide immediately at the inner cleaning of the stove.
The pellets can burn also thanks to chimney flue depression
without the aid of the fume fan. Have the fume fan immediately
replaced. It can be noxious to health to let the stove running
without fume fan.