Motion detector top unit Standard
1
Safety instructions
Electrical devices may be mounted and connected only by electrically skilled
persons.
Serious injuries, fire or property damage are possible. Please read and follow the
manual fully.
Danger of electric shock. Always disconnect before carrying out work on the device
or load. In so doing, take all the circuit breakers into account, which support danger-
ous voltages to the device and or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage
because – depending on the insert used – mains potential even is applied on the load
when the device is switched off. Always disconnect before carrying out work on the
device or load. To do so, switch off all associated circuit breakers.
Do not press on the sensor window. Device can be damaged.
The device is not suitable for use as a burglar alarm or other alarm.
This manual is an integral part of the product, and must remain with the customer.
2
Intended use
–
Automatic switching of lighting depending on the heat motion and ambient
brightness
–
Operation with flush-mounted insert for dimming or switching or 3-wire exten-
sion
–
Wall installation on flush-mounted insert
Product characteristics
–
Extension of the detection field in combination with 3-wire extension
–
Operation with 2-wire or 3-wire extension, rotary extension, or push-button
–
Switch on with last saved brightness or saved switch-on brightness, with dim-
ming insert
–
Switch-on brightness can be saved permanently via extension, with dimming
insert
–
Dimming light via extension with dimming insert
Order no. 5373 .., 5375 ..
–
Fixed run-on time
–
Selectable sensitivity
–
Selectable brightness threshold
Order no. 5379 ..
–
Fixed sensitivity
–
Selectable run-on time
–
Selectable brightness threshold
32599612
10870634
19.07.2023